The Kane 100-1 tests for ambient CO and ambient CO

2

 concentrations. 

 
The large display shows 2 readings at a time and all data can be printed via 
an optional infrared printer. The printed data can be 'live' data or 'stored 
data'. 
 
The KANE 100-1 is controlled using 4 buttons and a rotary dial.  
 
The four buttons (from left to right) 
  
switch the instrument on and off,  
print actual or saved data, switch the backlight on and off,  
switch the pump on and off, change the top line data display, 
save data or temporarily hold or ‘freeze’ the current reading. 
 
The buttons with UP, DOWN and ENTER arrows also change settings 
such as date, time, when in menu mode. 
 
The rotary dial changes the display’s 2

nd

 line and selects access to the 

menu to make changes to the date, time, fuel, etc. 
 
The KANE 100-1 can store up to 255 sets of readings. 
 
The Kane 100-1 is powered by internal re-chargeable NiMH batteries.  
The internal battery will power the analyser for about 6Hr, from full 
charge.   
 
The KANE 100-1 has a protective rubber sleeve with a magnet for 
“hands–free” operation. 
 

NOTE:

  Fresh air is referred to in this manual.  Sometimes it may be 

convenient to use thin flexible tubing (min ID. 3mm.) to supply fresh 
outside air, if a tube is used ensure that the inlet  is at least 1 meter away 
from any possible source of CO

2

 such as an open window.   

Fuel combustion of any sort  may cause high and fluctuating levels of CO

2

 

over surprisingly large areas.  Exhaled breath can easily reach 10,000 to 
20,000ppm. 

Содержание 100-1

Страница 1: ...onoxide and Ambient Carbon Dioxide Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel 44 0 1707 375550 Fax 44 0 1707 393277 E mail sales kane co uk www kane co...

Страница 2: ...when in menu mode The rotary dial changes the display s 2nd line and selects access to the menu to make changes to the date time fuel etc The KANE 100 1 can store up to 255 sets of readings The Kane 1...

Страница 3: ...witched off 2 BEFORE USING THE ANALYSER EVERY TIME Check the water trap is empty and the particle filter is not dirty To empty the water trap unplug its rubber stopper and re plug once it is empty To...

Страница 4: ...0ppm in fresh air allow a few seconds after each button press for readings to settle and then press ENTER to confirm After ENTER is pressed it will take about 4 seconds before the unit is ready to res...

Страница 5: ...keys to change settings such as time and date when the rotary dial is turned to MENU Enter key to Hold or Store readings In normal operation not MENU the ENTER key is used to either HOLD the readings...

Страница 6: ...on top of the analyser Switching PUMP on off The analyser normally operates with the pump on Press the PUMP key quickly to switch the pump off and on When the pump is switched off the analyser displa...

Страница 7: ...ribed fully below to select and change the following functions 1 Time Uses Military time as standard 7am 07 00 7pm 19 00 2 Date with date format selection 3 Pump speed control full speed or quiet mode...

Страница 8: ...final logical ENTER is pressed no changes are made Note in AIR ZERO this mode will continue until terminated by the pressing of ENTER You can choose from the menu fresh air zeroing which allows CO2 t...

Страница 9: ...ber within the range of data stored up to 255 maximum In view mode only stored readings wrap round so that using the up key you pass from maximum reading back to the first reading or using the down ke...

Страница 10: ...You can maximize the number of stored readings by switching the pump to low speed QUIET and after initiating store switch the pump off Typically if the batteries are fully charged you will be able to...

Страница 11: ...fresh air zero or true zero Use the UP or Down button to chose and ENTER to select Once zeroing has commenced it will continue until completed whatever you do with the rotary dial Fresh air zero shoul...

Страница 12: ...operating specifications In particular Do not exceed the probe s maximum temperature any plastic parts must not contact hot flues Do not exceed the temperature operating range Do not put the analyser...

Страница 13: ...ndard printouts are Instant print press print button KANE 100 1 CO CO2 MONITOR DATE 01 01 06 TIME 14 27 08 CO2 CO ppm ppm 950 12 Manually logged print via VIEW stored data KANE 100 1 CO CO2 MONITOR DA...

Страница 14: ...via MEMORY KANE 100 1 CO CO2 MONITOR AUTOLOG REPORT DATE 01 01 06 TIME 18 27 08 Start Time 06 6 04 14 00 00 Stop Time 06 6 04 17 59 00 No of readings 255 Max CO2 Av CO2 Max CO Av CO ppm ppm ppm ppm 95...

Страница 15: ...start up 8 PROBLEM SOLVING If any problems are not solved with these solutions contact us or an authorized repair centre Fault symptom Causes Solutions Batteries not holding charge Batteries exhausted...

Страница 16: ...NU appears on the top line NB You may be changing settings when you do this Rotate the dial to the required display position The unit will not turn off Do not hold down the on off button Try connectin...

Страница 17: ...4000 ppm 2000ppm 9999ppm Dimensions Weight Handset 1kg 2 2lb 200mm 7 9 x 45mm 1 8 x 90mm 3 5 Ambient Operating Range 0 C to 45 C 32 104 F 10 to 90 RH non condensing Battery Life 6 hours from full char...

Страница 18: ...tart up sequence in the location where the analyser will be used Switch on all localized electrical equipment capable of causing interference Check all readings are as expected A level of disturbance...

Страница 19: ...mg m3 8 hours 9ppm 10mg m3 Carbon Dioxide HSE Regulation EH40 sets the maximum occupational exposure limit at 5000ppm BSRIA recommend a maximum of 800ppm over an eight hour time weighted average ASHRA...

Отзывы: