15
Engine oil replacement or adding
Upon oil level decrease it is necessary to add the required quantity in order to
provide the correct generator operation. It is necessary to check the oil levels
according to technical maintenance schedule.
To replace engine oil, perform the following actions:
1. Make sure that the generator is set on flat level surface.
2. Place a drain oil holding tank under the engine.
3. Turn the drain cap, located under the oil-depth gage cap in the engine, by
means of a 10mm hexagon spanner.
4. Wait till the oil drains.
5. By means of a funnel, pour the advanced purification engine oil to the
crankcase. The funnel is not included. Oil level after filling has to be close to the
upper part of oil filler.
6. Put the drain cap back and tighten it well.
Pic 6
30
-20 -10 0
10 20 30 40
0
C
5W-30, 10W-30
Pic 7
FILL TO
HERE
Crank case
Oil gage cap
Содержание KS 6100HDE
Страница 23: ...22 ...