*Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical condition of the 

generator.

To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.

The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), 

and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum perfor-

mance in terms of the declared specifications.

In the event of deviations from these environmental indicators, the generator performance may vary.
Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to 

extend its service life.

It is recommended to ground the generator before operating it for the first time. Before starting the device, remember 

that the total power of the connected power consumers should not exceed the nominal power of the generator.

TERMS OF USE OF INVERTER GENERATOR

4

GENERATOR OPERATION

5

Make sure that the control panel, the blinds and the underside 

of the inverter are well cooled and protected against the ingress 

of small solids, dirt, and water. Improper operation of the cool-

er can cause damage to the motor, inverter or alternator.

IMPORTANT!

DC FUSE

DC FUSE

The DC protector automatically switches to “OFF” when the current of the operating electrical device is higher than the 

rated current. To use this equipment again, turn on the DC fuse again by pressing the “ON” button.

OIL LEVEL INDICATOR

OIL LEVEL INDICATOR

When the oil level falls below the level required for operation, the oil level indicator lights up, and then the engine stops 

automatically. The engine will not start until oil is added.
AC INDICATOR

AC INDICATOR

When the generator is running and producing electricity, the AC indicator light is on.

OVERLOAD INDICATOR

OVERLOAD INDICATOR

The overload indicator lights up when the connected generator is overloaded, the inverter control unit overheats or the 

AC output voltage rises.
If the overload indicator goes on, the engine will continue to operate, but the generator will no longer produce electricity. 

In this case, you must perform the following steps:

1. Turn off all connected electrical appliances and stop the engine.

2. Reduce the total power of the connected devices until the nominal power of the generator is reached.
3. Check if the vent grid is clogged. Remove excess dirt or debris, if any.
4. After checking, start the engine.

The overload indicator may light up within several seconds after 

start-up or when connecting electrical devices requiring a high start-

ing current, such as a compressor or voltage indicator. However, this 

is not a malfunction.

IMPORTANT!

If the DC fuse turns off, reduce the load of the connected electrical 

device. If the DC protector turns off again, stop operation and 

contact your nearest K&S BASIC

®

 service center.

IMPORTANT!

konner-sohnen.com

   

|

    4

Содержание KSB 22i S

Страница 1: ...EN Please read this manual carefully before use OWNER S MANUAL Inverter Generator in Soundproof Housing KSB 22i S...

Страница 2: ...way from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to savepaper and leave We care about the environment therefore we consider it expedient...

Страница 3: ...application and the system used IMPORTANT PRECAUTIONS WHEN WORKING WITH GASOLINE GENERATOR 1 2 Do not start the generator operation upon presence of electric load Disconnect the load before you stop t...

Страница 4: ...tank volume l 4 Working time at 50 load gasoline fuel h 5 0 Noise level Lpa 7m Lwa dB 62 87 Engine model KSB 100i Engine volume cm3 79 7 Engine type gasoline 4 stroke cycle engine Engine power hp 3 3...

Страница 5: ...current of the operating electrical device is higher than the rated current To use this equipment again turn on the DC fuse again by pressing the ON button OIL LEVEL INDICATOR OIL LEVEL INDICATOR Whe...

Страница 6: ...s before you start the engine Do not connect any devices before you start the engine GETTING STARTED 7 Do not change the controller settings in terms of the amount of fuel or speed governor this adjus...

Страница 7: ...s be sure to change the oil It is better to drain oil while the engine is still hot after operation to ensure quick and complete oil draining 3 Check and clean the air filter fuel filter and spark plu...

Страница 8: ...den Ziehen Sie die Schraube fest Brin gen Sie den Geh usedeckel des Generators wieder an Lassen Sie den Generator mit Fl ssiggas laufen D KS 22i S The ECON switch must be set to OFF to increase engine...

Страница 9: ...operating hours Every 6 months or 100 operating hours Every year or 300 operating hours Motor oil Level check Replacement Air filter Check Cleaning Replacement Spark plug Cleaning Replacement Fuel tan...

Страница 10: ...K PLUGS TECHNICAL MAINTENANCE 12 Spark plug has to be intact without soot deposits and to have a correct gap SPARK PLUG VERIFICATION SPARK PLUG VERIFICATION 1 Remove the cap from the spark plug 2 Remo...

Страница 11: ...el tank cap and fuel filter 2 Clean the filter with gasoline 3 Wipe the filter and replace it 4 Replace the fuel tank cap Make sure that the fuel tank cap is tight STORAGE 15 The generator must be sto...

Страница 12: ...he event of errors or corrections not authenticated by the seller s seal or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality ar...

Страница 13: ......

Страница 14: ...de Kundendienst technische Kundendienst technische Fragen und Unterst tzung Fragen und Unterst tzung support dimaxgroup de Garantie Reparatur und Garantie Reparatur und Service Service service dimaxgr...

Отзывы: