WORKING WITH THE DEVICE

5

  

  

OIL LEVEL INDICATOR

OIL LEVEL INDICATOR

When the oil level falls below the level required for operation, the oil level indicator lights up, and then the engine 

stops automatically. The engine will not start until oil is added.

  

  

AC INDICATOR

AC INDICATOR

When the generator is running and producing electricity, the AC indicator light is on.

  

  

OVERLOAD INDICATOR

OVERLOAD INDICATOR

FOR MODELS KSB 30

FOR MODELS KSB 30

ii S, KSB 40

 S, KSB 40iiE S: 

E S: 

Once the generator is working in the normal mode, output voltage light is 

green. In case of overload, indicator lights red. After 2 minutes working in overload mode, protection device switches 

on and turns off the power generation to protect the connected electrical equipment and generator. In the event 

of a short circuit, protection device immediately shuts off electricity. In both cases, indicator is blinking red, but the 

engine does not stop.
Restart the engine to make the generator produce electricity again.

The overload indicator may light up within several seconds after 

start-up or when connecting electrical devices requiring a high 

starting current, such as a compressor. However, this is not a 

malfunction.

IMPORTANT!

  

  

DC FUSE (EXCEPT FOR MODEL KSB 30

DC FUSE (EXCEPT FOR MODEL KSB 30

ii S)

 S)

The DC protector automatically switches to “OFF” when the current of the operating electrical device is higher than the 

rated current. To use this equipment again, turn on the DC fuse again by pressing the “ON” button.

RESET BUTTON FOR MODEL KSB 21

RESET BUTTON FOR MODEL KSB 21

ii S: 

 S: The RESET button has a built-in overload indicator. When approaching the 

overload condition, the indicator starts flashing. The overload indicator lights up when the connected generator is 

overloaded, the inverter control unit overheats or the AC output voltage rises.

If the overload indicator goes on, the engine will continue to operate, but the generator will no longer produce 

electricity. In this case, you must perform the following steps:

1. Turn off all connected electrical appliances.

2. Reduce the total power of the connected devices until the nominal power of the generator is reached.

3. Press the RESET button once to restore socket voltage. After that the WORKING MODE indicator will flash 3 times 

and the power supply will be restored.

If the DC fuse turns off, reduce the load of the connected electrical 

device. If the DC protector turns off again, stop operation and 

contact your nearest K&S Basic

®

 service center.

IMPORTANT!

  

  

FUEL TANK CAP AIR VENT (FOR MODEL 

FUEL TANK CAP AIR VENT (FOR MODEL KSB 21

KSB 21

ii S)

 S)

The fuel cap is equipped with a vent for air supply to the fuel tank. When the engine is running, the vent must be in 

the “ON” position (OPEN). This will allow fuel to enter the carburetor for engine operation. When the generator is not 

in use, close the vent to the “OFF” position.

  

  

GROUND TERMINAL

GROUND TERMINAL

The ground terminal forms a ground line to prevent electric shock. If the electrical appliance is grounded, the 

generator must also be grounded.

Make sure that the control panel, the blinds and the underside 

of the inverter are well cooled and protected against the ingress 

of small solids, dirt, and water. Improper operation of the cooler 

can cause damage to the motor, inverter or alternator.

IMPORTANT!

konner-sohnen.com

   

|

    6

Содержание KSB 21i S

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL EN Inverter Generator in Soundproof Housing KSB 21i S KSB 30i S KSB 40iE S...

Страница 2: ...he front control panel and not less than 50 cm on each side including the upper part of the generator Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We...

Страница 3: ...evices which can generate current pulses and direct energy towards the generator voltage stabilizers devices with electronic brakes on grid and hybrid inverters etc IMPORTANT The generator and power c...

Страница 4: ...starter 1 Fuel tank cap 2 Transport handle only for model KSB 40iE S 3 Control panel 4 Manual starter 5 Brake 6 Battery only for model KSB 40iE S MODEL KSB 21 MODEL KSB 21ii S S MODELS MODELS KSB 30...

Страница 5: ...fler 10 Carburetor 11 Air filter 12 Spark plug 13 Maintenance cover for motor oil change MODEL KSB 30 MODEL KSB 30ii S CONTROL PANEL S CONTROL PANEL MODEL MODEL KSB 40 KSB 40i i S S CONTROL PANEL CONT...

Страница 6: ...dedtogroundthegeneratorbeforeoperatingitforthefirsttime Beforestartingthedevice remember that the total power of the connected power consumers should not exceed the nominal power of the generator TERM...

Страница 7: ...he RESET button has a built in overload indicator When approaching the overload condition the indicator starts flashing The overload indicator lights up when the connected generator is overloaded the...

Страница 8: ...O HERE Use only unleaded gasoline Using leaded gasoline can cause serious damage to the inside of the engine IMPORTANT Beforestartingtheengine Beforestartingtheengine makesurethattheratedpowerofpowerc...

Страница 9: ...onsible for the installation and electrical connection of the equipment according to local laws and regulations The manufacturer assumes no liability for improper connection of the equipment or for an...

Страница 10: ...ot connect two or more devices at a time The start up of many devices requires high power Devices should be connected one at a time according to their power rating Do not connect any power consumers w...

Страница 11: ...om generators ensures total rated output power of these generators When the generators are connected in parallel the power loss is 0 2 kW of the total rated power that can be obtained During parallel...

Страница 12: ...the filter element thoroughly in warm soapy water 6 Dry the sponge filter 7 Soak a dry filter element in engine oil then squeeze out excess oil SPARK PLUGS TECHNICAL MAINTENANCE 13 Spark plug has to b...

Страница 13: ...o cool slightly and drain the warm oil Oil will drain faster and easier from a warm engine ATTENTION DANGER MODEL KSB 21 MODEL KSB 21ii S S 1 Place the generator on a flat surface 2 Loosen the screws...

Страница 14: ...rrections not authenticated by the seller s seal or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality are accepted and the warra...

Страница 15: ...DELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODEL KSB 21 MODEL KSB 21ii S S MODEL KSB 21 MODEL KSB 21ii S S konner sohnen com 14 1 1...

Страница 16: ...SB 40 KSB 40iiE S E S MODELS KSB 30 MODELS KSB 30ii S S KSB 40 KSB 40iiE S E S MODEL KSB 21 MODEL KSB 21ii S S MODEL KSB 21 MODEL KSB 21ii S S 1 1 2 2 3 3 4 4 3 3 1 1 1 1 2 2 2 2 3 3 5 5 4 4 konner so...

Страница 17: ......

Страница 18: ...de Kundendienst technische Kundendienst technische Fragen und Unterst tzung Fragen und Unterst tzung support dimaxgroup de Garantie Reparatur und Garantie Reparatur und Service Service service dimaxgr...

Отзывы: