K&S BASIC KSB 21i S Скачать руководство пользователя страница 14

GENERATOR STORAGE

15

The generator must be stored in a dry, well-ventilated area that is free from dust. Keep away from children and 

animals.

Generator  should  always  remain  ready  for  operation.  Therefore 

in  case  of  device  malfunctions,  they  are  to  be  repaired  before 

dismounting the generator for storage.

IMPORTANT!

  

GENERATOR LONG-TERM STORAGE

If the generator will not be used for a long time, it is recommended to:

- Drain the fuel into the tank.
- Drain the motor oil.
- Pull the manual starter until a slight resistance is felt so that the inlet and drain valves get closed.
- Clean the generator from dirt and dust.
When starting the generator after long-term storage, proceed as above in the reverse order.

GENERATOR TRANSPORTATION

16

GENERATOR AND BATTERY

UTILISATION

17

For easy generator transportation use packaging, which generator was sold in. Secure the box with the generator to 

avoid tipping it on the side of the carriage. Before moving the generator drain the fuel and disconnect the terminals 

of the battery (if this model has a battery).

To move the generator from one place to another lift it by holding the frame (if generator has construction with open 

frame). If generator has an silent cover, use transportation handles. Be careful, do not expose your feet under the 

generator.

To prevent damage to the environment separate generator and battery from ordinary waste and recycle them in the 

safest way passing a special place for disposal.

Potential faults and troubleshooting methods, as well as average device capacities can be found in thefull version 

of the manual.

WARRANTY SERVICE TERMS

18

The international manufacturer warranty is 1 year. The warranty period starts from the date of purchase. 

In cases when warranty period is longer than 1 year according to local legislation please contact your local 

dealer. The Seller which sells the product is responsible for granting the warranty. Please contact the Seller for 

warranty. Within the warranty period, if the product fails because of defects in the production process, it will 

be exchanged on the same product or repaired.
The warranty card should be kept throughout the warranty period. In case of warranty card loss, a second 

one will not be provided. The customer must provide the warranty card and buyer`s check during request 

for  repair  or  exchange.  Otherwise,  the  warranty  service  will  not  be  provided.  The  warranty  card,  attached  to

 

the product during sale, should be correctly and fully completed by the retailer and customer, signed and 

stamped. In other cases, warranty is not considered as valid.
Provide clean product to the service center. Parts, that must be replaced, are the property of the service center.

www.ks-power.de/en

   

|

    29

Содержание KSB 21i S

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KSB 21i S KSB 21i KSB 35i KSB 31iE S EN...

Страница 2: ...erator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care abo...

Страница 3: ...cylinder volume cm3 79 5 119 212 149 8 Engine type gasoline 4 stroke cycle engine Outlets 2 16 Power factor cos 1 Fuel tank volume l 4 0 10 13 6 Crankcase volume l 0 4 0 4 0 6 0 8 Engine start manual...

Страница 4: ...ontrol switch ECON 7 Grounding 8 Elactrostart for model KSB 31iE S 9 16A outlets MODELS KSB 21i S KSB 31iE S 1 Transport handles 2 Fuel tank cap 3 Control panel 4 Starter 5 Maintenance panel 6 Ventila...

Страница 5: ...ne oil is insufficient Add oil and restart IMPORTANT TERMS OF USE 4 When starting operating the generator it s recommended to ground it Before starting the unit remember that the total power of consum...

Страница 6: ...lt you get less fuel consumption and noise OFF When the ECON switch is turned to OFF the engine runs at the rated speed 4500r min regardless of whether is a load connected or not Tip The overload indi...

Страница 7: ...e are higher than standard atmospheric conditions Additionally the load must be reduced when using in a confined area as generator cooling is affected Recommended engine oil SAE 10W 30 SAE 10W 40 Reco...

Страница 8: ...e engine The ECON unit operates in normal mode after the specified period of time while the mode switch is in the ON position When using the generator be careful You can use the generator if the voltm...

Страница 9: ...is on 5 Turn on any electric devices Before operating the generator connect ground wire to ground terminal Please consult with a specialist before using the ground terminal IMPORTANT IMPORTANT Tip Ma...

Страница 10: ...DC protector turns off automatically if current above the rated flows during battery charging To restart charging the battery turn the DC protector on by pressing its button to ON If the DC protector...

Страница 11: ...every 25 operating hours If the engine is often running in dusty or other harsh conditions please clean the air filter every 10 hours If you missed the maintenance time perform it as soon as possible...

Страница 12: ...mediately after stopping the engine The oil is hot and should be handled with care to avoid burns ATTENTION DANGER Do not tilt the generator while adding oil to the engine This can lead to overfilling...

Страница 13: ...oid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair MUFFLER SCREEN AND SPARK ARRESTER TECHNICAL MAINTENANCE 13 1 Remove the...

Страница 14: ...ose your feet under the generator To prevent damage to the environment separate generator and battery from ordinary waste and recycle them in the safest way passing a special place for disposal Potent...

Страница 15: ......

Страница 16: ......

Страница 17: ...51143 K ln www ks power de info dimaxgroup de Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua s...

Отзывы: