![K&S BASIC KS 2200A Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/kands-basic/ks-2200a/ks-2200a_owners-manual_3078565019.webp)
18
21. TROUBLESHOOTING
Fault
Probable cause
Remedy
Engine will not
start
The engine start key (button)
is set to the OFF position
Set the engine start key
(button) to the ON position
The fuel valve is set to the “CLOSE”
position
Move the fuel valve to the
“OPEN” position
Air choke is open
Close the air choke lever
Fuel tank is empty
Fill in the fuel tank
Fuel tanks contains dirty or
used fuel
Replace fuel in the fuel tank
Spark plug smoked or
damaged; wrong distance
between electrodes
Clean the spark plug or
replace it with a new one; set
the correct distance between
the electrodes
Reduced engine
power / troubled
engine start
Fuel tank is dirty
Clean the fuel tank
Air filter is dirty
Clean the air filter
Water in fuel tank and/
or carburetor; clogged
carburetor
Empty the fuel tank, fuel line
and carburetor
Wrong distance between
spark plug electrodes
Set the correct distance
between the electrodes.
Engine overheating
Cooling fins are contaminated
Clean the cooling fins
Air filter is dirty
Clean the air filter
Engine starts, but
no output voltage
Circuit breaker tripped
Set the circuit breaker to ON
Connection cables of poor
quality
Check cables for normal
operation; replace, if
extension cable is used
Faulty connected device
Try connecting another
device
Generator works,
but does not support
connected electrical
devices
Device overload
Try to connect less equipment
Short circuit of one of the
connected devices
Try disconnecting the faulty
device.
Air filter is dirty
Clean the air filter
Insufficient engine speed
Contact the service center