Страница 2: ...CIFICATIONS 8 9 7 GENERATOR DELIVERY PACKAGE 10 8 CONTROL PANELS 10 9 COMMISSIONING 11 10 GETTING STARTED 11 10 1 Checking the fuel level 11 10 2 Checking the oil level 11 11 ENGINE START 12 11 1 Gasoline Powered Generator Engine Start 12 12 ENGINE STOP 13 12 1 Gasoline Powered Generator Stop 13 13 MAINTENANCE 13 14 RECOMMENDED MAINTENANCE SCHEDULE 14 15 SPARKPLUGMAINTENANCE 14 16 RECOMMENDED OILS...

Страница 3: ...ake changes intheproductdesign configurationandconstruction Theimagesanddrawings in this manual are for reference only and may differ from the actual components and inscriptions on the products Contactinformationthatyouarefreetouseincaseofanyproblemscanbefound at the end of this manual All information in this manual is correct to the best of ourknowledgeandbeliefatthedateofitspublication Thecurren...

Страница 4: ...oisture to enter the generator as this increases the risk of electric shock _Avoid direct contact with grounded surfaces pipes radiators etc _Be careful when working with the power cord Replace it immediately in case of damage as damaged power cord increases the risk of electric shock _All connections of the generator to the mains must be carried out by a certified electrician _Connect the electri...

Страница 5: ... at least 1 m away from explosive and flammable substancesandobjectssinceitsengineheatsupduringoperation Donotfillthefueltankwhentheengineisrunning Donotsmokewhilerefueling _ Forthegenerator A 92gasolineisrecommended Afterfillingthetank removeall excessfuelfromthesurface Donotusekeroseneorotherfuel Otherwise theengine maybedamaged Observethefueltankwhilefillinginordertoavoidoverfilling _ Do not to...

Страница 6: ...s are life threatening c _Do not operate or store the device in high humidity environments d _Do not smoke while operating the generator e _The device generates electricity Observe safety precautions to avoid electric shock f _ Read this owner s manual carefully before operating the device g _Do not touch the generator with wet or dirty hands h _Observe fire safety regulations do not operate the g...

Страница 7: ...fuel valve The ON position means open and the OFF position means closed Indicates the direction of opening the air choke Fuel level indicator The icon on the left indicates that the fuel tank is full and the icon on the right indicates that the fuel tank is empty Maintenance information in the language of the country where the generator is sold can be found in the Maintenance section Note on the r...

Страница 8: ...ternator 12 Spark plug 5 GENERALVIEW AND COMPOSITION OF THE GASOLINE POWERED GENERATOR Fig 3 PLEASE NOTE 2 1 3 4 5 6 7 8 9 12 10 11 The manufacturer reserves the right to make changes in the product design configuration and construction Illustrations in this manual are for reference only and may differ from actual components and inscriptions on the products ...

Страница 9: ...2V A 12 8 3 12 8 3 12 8 3 Engine model KS B80 KS B170 KS B170 Engine type Gasoline powered four stroke Gasoline powered four stroke Gasoline powered four stroke Power output hp 2 9 5 5 5 5 Crankcasecapacity cm3 0 37 0 6 0 6 Enginecapacity cm3 80 163 163 Voltage regulator AVR AVR AVR Engine start Manual Manual Manual Power factor cosφ 1 1 1 Dimensions LxWxH mm 470 365 380 605 445 450 605 445 450 Ne...

Страница 10: ...6 Output 12V A 12 8 3 12 8 3 Engine model KS B200 KS B200 Engine type Gasoline powered four stroke Gasoline powered four stroke Power output hp 6 5 6 5 Crankcase capacity cm3 0 6 0 6 Engine capacity cm3 196 196 Voltage regulator AVR AVR Engine start Manual Manual Power factor cosφ 1 1 Dimensions LxWxH mm 605 445 450 605 445 450 Net weight kg 43 43 Protection class IP23M IP23M Max altitudeaboveseal...

Страница 11: ...5 4 7 GENERATOR DELIVERY PACKAGE _ 1 Generator _ 2 Packaging _ 3 Owner s manual _ 4 Spark plug wrench USE CAREWHENTHE GENERATOR IS RUNNING You can use the generator if the voltmeter indicates a value of 230 V 10 50 Нz _Monitor the voltmeter and stop the generator if the value is too high _Avoid using 12V voltage simultaneously with 230V ...

Страница 12: ...lling procedure are given below Tocommissionthegenerator followthemaintenancerecommendationsforthe first month or twenty hours of operation whichever comes first contained in the Maintenance section Fig 5 Fig 6 10 2 CHECKINGTHE OIL LEVEL 1 Wear protective gloves to avoid getting oil on your skin 2 Unscrew the oil dipstick and wipe it out with a clean cloth 3 Insert the dipstick without screwing it...

Страница 13: ...handle and slowly pull it until resistance is felt Pull the starter cord to the full length with a sharp movement 4 Set the air choke to the OPEN position Before connecting any devices to the generator make sure that they are in good condition If the device that was connected suddenly stopped or failed immediately disconnect the power using a safety switch disconnect the device and check it out Do...

Страница 14: ...l not be liable for any damage caused by failure to perform maintenance work Such damage also includes _Damage resulting from the use of non original spare parts _Corrosive damage and other effects of improper storage of equipment _Damage caused by maintenance work performed by unskilled technicians The current list of service centers can be found on the exclusive importer s website www ks power c...

Страница 15: ...an important element that ensures proper engine operation It must be intact properly gapped and free of deposits Inspecting the spark plug 1 Remove the spark plug cap 2 Unscrew the spark plug with the appropriate wrench 3 Visually inspect the spark plug If the spark plug is damaged it must be replaced It is recommended to use the F7TC spark plug 4 Measure the gap It should be in the range of 0 7 0...

Страница 16: ...according to the maintenance schedule To drain oil proceed as follows 1 Wear protective gloves to avoid getting oil on your skin 2 Place an oil drain tray under the engine 3 Unscrew the drain cap located on the engine under the dipstick cap with a 10 mm wrench for generators up to 3 0 kW or 12 mm for generators above 3 0 kW 4 Wait for the oil to drain 5 Replace the drain cap and tighten securely 6...

Страница 17: ...housing 4 Clean the filter element thoroughly in warm soapy water 5 Dry the sponge filter 6 Soak a dry filter element in engine oil and then squeeze out excess oil Replace the air filter every 50 operating hours of the generator every 10 hours in dirty conditions Cover spring Cover spring Clean Squeeze out Soak Squeeze out Filter Air filter cover 2 1 4 3 Fig 11 PLEASE NOTE Oil pollutes soil and gr...

Страница 18: ...ternal parts of the generator and engine especially cooling fins must be thoroughly cleaned _Unscrew the carburetor float chamber screw empty the chamber _Remove the spark plug _Unscrew the oil drain screw and drain the oil _Add a teaspoon of engine oil 5 10 ml to the cylinder After that pull the starter cord several times so that the oil spreads along the cylinder walls _Replace screw in the spar...

Страница 19: ... is dirty Clean the air filter Water in fuel tank and or carburetor clogged carburetor Empty the fuel tank fuel line and carburetor Wrong distance between spark plug electrodes Set the correct distance between the electrodes Engine overheating Coolingfinsarecontaminated Clean the cooling fins Air filter is dirty Clean the air filter Engine starts but no output voltage Circuit breaker tripped Set t...

Страница 20: ...1000 Radio 50 250 Grill 1200 2300 Oven 1000 2000 Fridge 100 150 TV set 100 400 Perforator 600 1400 Drill 400 800 Freezer 100 400 Grinder 300 1100 Circular saw 750 1600 Crank gear 650 2200 Jigsaw 250 700 Planer 400 1000 Compressor 750 3000 Water pump 750 3900 Bench saw 1800 4000 Electric mower 750 3000 Electric motors 550 5000 Fans 750 1700 High pressure unit 2000 4000 Air conditioner 1000 5000 ...

Страница 21: ...eaning from dust and dirt appropriate adjustment maintenance oil change etc If the product is used for business related purposes If faults are detected which have been caused by product overload Signs of overload are molten or discolored parts as a result of high temperatures damaged cylinder or piston surfaces degraded piston rings or connecting rod bushes The warranty does not cover the failure ...