background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
USER MANUAL 

KLB54W3RGBAW  

Содержание KLB54W3RGBAW

Страница 1: ...USER MANUAL KLB54W3RGBAW ...

Страница 2: ... 4 main function 5 DMX controller function 5 Display operation instruction 5 Manual instruction 8 Operating control instruction 11 XRL connection instruction 12 Connection picture 13 Exploded Views 15 Luminance list 16 Problem analyze 17 Technical specification 18 ...

Страница 3: ...nds LED Each kind of LED can be independently dimmer It uses power switch performs low weight and consumption stable capability and long life The built in program includes dimmer strobe eotic gradual change fading and so on International standard DMX 512 signal is requested Packing list KLB54W3RGBAW 1 pc Hang locks 2 pcs bracket 1 pc Power in cable 1 pc The use manual Warranty Card Safety Informat...

Страница 4: ...anical structure have been received in good condition and appear no damage This light is designed for indoor use working temperature is lower than 40 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflammable and explosive items ornaments in 0 5 meters away Yellow green cabling earthling safety no flicker when the fixture is...

Страница 5: ...ted master slave interconnected multi machine control using switching power supply to protect the LED to work well Lens 15 25 45 DMX512 channels 5CH 9CH 14CH 15CH 30CH DMX Control Function 1st pixel 2nd pixel 3rd pixel 4th pixel 5th pixel 6th pixel 5CH Channel DMX Value Control Function 1CH 0 255 R 0 100 from 1st to 6th pixel 2CH 0 255 G 0 100 from 1st to 6th pixel 3CH 0 255 B 0 100 from 1st to 6t...

Страница 6: ...e value is greater the speed is faster 50 74 Mode 3 the value is greater the speed is faster 75 99 Mode 4 the value is greater the speed is faster 100 124 Mode 5 the value is greater the speed is faster 125 149 Mode 6 the value is greater the speed is faster 150 174 Mode 7 the value is greater the speed is faster 175 199 Mode 8 the value is greater the speed is faster 200 224 Mode 9 the value is g...

Страница 7: ...xel to the 6th 0 0 9 invalid 11CH 10 255 RGBAW mixing 3 0 2 Close strobe 12CH 3 255 Strobe slow fast 3 0 4 invalid 5 24 Mode 1 the value is greater the speed is faster 25 49 Mode 2 the value is greater the speed is faster 50 74 Mode 3 the value is greater the speed is faster 75 99 Mode 4 the value is greater the speed is faster 100 124 Mode 5 the value is greater the speed is faster 125 149 Mode 6...

Страница 8: ...vice the 6pixel into 6 group each group 1pixel each group 5CH RGBAW 5CH 6 Display Operation MENU access the menu or return to a previous menu option ENTER select the current menu option UP menu selection or parameter increments DOWN menu selection or parameters decrease Manual Instruction ...

Страница 9: ...annels select and DMX address setting ADDR is DMX address settings for 001 512 CHS is the number of DMX receiving channels 5CH 9CH 14CH 1 press the MENU button to exit the setting mode and then press the UP DOWN key until shows DMX channels 2 The first press ENTER key modify the DMX address the cursor will glinting in the ADDR s last value press UP DOWN key to modify the DMX address 3 The second p...

Страница 10: ...o strobe Operation ENTER UP DOWN MENU Built in programs PR00 the number of built in programs PR00 PR09 FL00 FADE strobe speed Fl00 Fl99 Fl00 is 0 Fl99 is the slowest SP00 program changes speed sp00 sp99 sp00 is the fastest Operation ENTER UP DOWN MENU Gradient mode RGB gradient mode speed adjustment for the SPEED 0 20 Operation ENTER UP DOWN MENU ...

Страница 11: ... master as long as it is not set in a DMX mode whatever other modes it is And it send out the signal so that the slave synchronous with it To avoid the host signal and DMX512 signals interfere with each other should cut off the DMX512 signals The signal lines are longer than 60 meters 20 lamps should increase a signal amplifier Slave he Slave must be set in DMX mode and the address code should be ...

Страница 12: ...other connect to the female Noted In order to avoid failures and interference signal transmission We connect a resistance 120Ω 1 4W at the end of the DMX connecting as below The Conversion between 3pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN please use 1pc 5PIN to 3PIN cable ...

Страница 13: ...Connecting picture Electrical connections ...

Страница 14: ...Light board Light Connecting picture ...

Страница 15: ...Exploded views ...

Страница 16: ...Luminance list ...

Страница 17: ...oose Change the main board to see if it is normal Chang the display LED not light When connect to the electricity did the led flash one time If so the power source is normal If not please check if the switch and the transformer has power out Check if the power input of the IC board is normal Check if the cable connect to the display loose Change the main board to see if it is normal Chang the disp...

Страница 18: ... Lamp Spec R 12PCS G 12PCS B 12PCS A 12PCS W 6PCS Life span 50000 100000 hours Control mode stand alone master and slaver Channel 5CH 9CH 14CH 15CH 30CH Beam Angle 15 25 45 Protection rating IP20 Anti electricity intension 1 5KV Insulation Resistance 2MΩ Size 609 190 104mm Net Weight 7 7KG ...

Страница 19: ...Copyright 2012 KANDOLITE All rights reserved Due to continuous improvements and innovations specifications may change without notice ...