Factory setting for 2Z-KHGX-LPG: G30-50mbar
Factory setting for other Models: G20-20 mbar - G 25-25 mbar
At 15°C and 1013 mbar-dry gas
P.C.I.G20 37.78 MJ/m³ P.C.I.G25.1 32.51 MJ/m³
P.C.I.G25 32.49 MJ/m³ P.C.I.G27 30.98 MJ/m³
P.C.I.G2.350 27.20MJ/ m³ P.C.I.G30 49.47MJ/Kg
Replacement of burner nozzle: loosen the nozzle with a
dedicated wrench(7).Fit the new nozzle, suitable for the required gas
type (see table above for reference)
。
After you have converted the cooktop to another gas type, make sure you have placed a
label containing that information on the appliance.
8 TABLE 2: HOW TO CONVERT GAS SOURCE
Adjustment of the reduced valve flow
Burners
Flame
Converting the
cooktop from LPG
to natural gas
Converting the
Cooktop from natural
Gas to LPG
Regular burners
Full flame
Replace the burner
Nozzle according
To the guidelines in
table 1
Replace the burner
Nozzle according
to the guidelines in
table 1
Saving flame
Loosen the adjustment
Spindle (see fig.7 below )
And adjust the flame
Loosen the adjustment
Spindle (see fig.7 below )
And adjust the flame
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig.7 below).