K&F SONA 8 Скачать руководство пользователя страница 7

Operating Instructions

K&F SONA 8

KLING & FREITAG GMBH © 2016

Version 1.4

Page 7 of 21

3.3

Preventing Hearing Damage

Caution

Keep your distance from operating speakers. This equipment is capable of delivering sound
pressure levels in excess of 90 dB SPL, which may cause permanent hearing damage.

3.4

Protecting the Speakers / Operating Safety

In general, audio signals must not be overdriven. This may be caused by mixing consoles,
equalizers, effect equipment, etc. and should be indicated on this equipment. When a power
amplifier is overloaded at the output (clipping), then the amplifier should activate a clipping
warning signal. Power amplifiers can also be overloaded at the input circuit without the
amplifier signalling the clipping, i.e. when there is not sufficient headroom in the input
circuit. We, therefore, recommend turning up the power amplifiers all the way and adjusting
the level before the power amplifier in order to avoid overloading the input circuit. In any
case, the signal must be reduced as soon as it sounds unnaturally distorted.

Operations without CD 44 Controller:

To protect the speakers from being destroyed and to avoid fire hazard, they should
only be operated with professional power amplifiers with a maximum rated output
power of 500 W @ 8 Ohm.

If power amplifiers have power ratings lower than 250 W @ 8 Ohm, then it is
imperative that the amplifiers have clipping limiters. Alternately, you can also insert a
clipping limiter before the amplifier.

To protect the loudspeaker from mechanical damage when high SPL is required a
highpassfilter of 24 dB/oct. at 60 Hz has to be inserted into the signal chain.

Operations with CD 44 Controller:

For optimal performance and operating safety of the SONA 8 speakers we recommend
using the system controller K&F  CD  44.

When operating the loudspeaker with amplifers without clipping limiter and nominal
amplifier power less than 100 W requires to set a Limit Reduction of 3 dB for the K&F
CD 44 controller. You can find more detailed information about this option in the
K&F  CD  44 hardware operating instructions.

The destruction of speakers and the risk of fire as a result of a very rare power
amplifier or speaker defect may not be avoided by the controller in any case.

For damage caused by

overloading the speakers or

using power amplifiers with other than the recommended maximum output power

we do not assume warranty and excludes liability for possible consequential damage.

The following signals may damage the speakers:

clipping power amplifiers

permanent high-level signals with high frequency and continuous noise from feedback,

permanently distorted high-level signals,

noises, which occur when the amplifier is on while equipment is being connected,
disconnected or switched on.

Do not install devices in any of the following places:

where the devices are permanently exposed to direct sunlight.

where the devices are exposed to high moisture or rain.

where the devices are exposed to strong vibrations and dust.

Содержание SONA 8

Страница 1: ...ease Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Operating Instructions Translation of the original instructio...

Страница 2: ......

Страница 3: ...Safety 7 4 Wall and Ceiling Installation 8 4 1 Temporary alignment of the speakers 8 4 2 Outlet for Cable and Safety elements 8 4 3 Wall Mounting of the Speaker 10 5 Stand Installation 11 6 Proper Ali...

Страница 4: ...p This icon marks information provided for simplified use of the described products 1 2 About these operating instructions KLING FREITAG GMBH All rights reserved All specifications regarding the featu...

Страница 5: ...ball joint 4 Hexagon nut M10 17 mm spanner 5 Long nut hexagon M10 black version 16 mm spanner white version 17 mm spanner 6 Mounting plate with M10 bolt 7 Connection terminal cover with outlet for cab...

Страница 6: ...before use If there are signs of wear cracks or deformation etc replace the affected parts immediately Visual inspection also includes checking all screwed connections of supporting components The inf...

Страница 7: ...ers Alternately you can also insert a clipping limiter before the amplifier To protect the loudspeaker from mechanical damage when high SPL is required a highpassfilter of 24 dB oct at 60 Hz has to be...

Страница 8: ...the three hexagon socket srews only This way you can avoid having to tighten an hexagon socket screw that got covered by the Mounting Arm while you aligned the speaker Loosen this screw s just enough...

Страница 9: ...e safety eye in the speaker using the chain quick link Connect the speaker via the Speakon plug or the Phoenix connector First lay the safety element and then the speaker cable in the feedthrough slot...

Страница 10: ...mounting plate you can also mount the Mounting Arm with other suitable 10 mm bolts Screw the mounting plate onto the wall or ceiling using all four mounting holes Choose fasteners that are suitable fo...

Страница 11: ...ount a SONA 8 speaker on a stand you need the accessory Stand socket M10 1 For stand mounting you do not need the provided long nuts Unscrew them from the mounting arm and keep them for possible later...

Страница 12: ...anding systems result in a greater difference in volume between front and back seats than higher standing systems To simulate the correct alignment of the speakers beforehand there are various program...

Страница 13: ...e speakers at the amplifier is correct When simultaneously using power amplifiers from different manufacturers be sure to use the correct specific pin configuration It may be necessary to modify the p...

Страница 14: ...system If there is interference turn off all appliances in the reverse order and check all cable connections Successively turn up the individual power amplifier channels and send a signal with low vo...

Страница 15: ...al IEC 268 5 500 W program 1000 W Peak SPL 1 W 1 m 93 dB SPL Max SPL 1 m 124 dB SPL Components 8 low mid chassis 1 Hochtontreiber mit 45 mm Titanmembran CD Horn Impedance nominal 8 Ohm connectors behi...

Страница 16: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 16 of 21 11 Measuring Diagrams 11 1 Coverage SONA 8...

Страница 17: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 17 of 21 11 2 Frequency range SONA 8...

Страница 18: ...12 Dimensions with Mounting Arm 250 6 mm 9 866 inch 120 mm 4 724 inch 461 6 mm 18 175 inch 29 440 6 mm 17 346 inch 285 3 mm 11 233 inch 102 1 mm 4 018 inch 140 mm 5 512 inch 5 mm 0 197 inch 450 5 mm...

Страница 19: ...ossed out garbage can with a white bar below it The icon indicates that the equipment was distributed on or after 24 March 2006 and must not be disposed of through household waste KLING FREITAG GmbH i...

Страница 20: ...SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage used W...

Страница 21: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 21 of 21 Managing Director CEO...

Отзывы: