LED Codes
The programmer will give a brief green flash when plugged in to
target. When button is pressed, LED will flicker green during
programming. When programming has finished, these codes
appear.
Green Flashes
, 1 second interval: Programmed OK
2 Red Flashes
: Failed to enter ISP. Possible causes:
•
No device connected
•
Programmer speed too fast for target clock
3 Red Flashes
: EEPROM did not verify
4 Red Flashes
: Flash did not verify
5 Red Flashes
: Fuses/Lockbits did not verify
6 Red Flashes
: Program Limit reached
7 Red Flashes
: Device ID did not match
8 Red Flashes
: Empty programmer
9 Red Flashes
: Header checksum error
10 Red Flashes
: Flash checksum error
You can press button again to start programming when error codes
are still flashing.
TROUBLESHOOTING
Windows driver problems
If you get a driver error or FTDIxx.DLL not found, make sure that
you have run the install software from Kanda site and then plugged
in programmer, NOT the other way round.
The driver should appear as a "USB Serial Converter" in USB section
of Device Manager. Windows should do this automatically. If it does
not, please follow this procedure.