miniDaqu — Manual
9.4
Current
current is negligible, so a low current fuse can be used. Figure 25 illustrates
an example.
C
1
2
1
-
+
BAT
V
GND
3
+5 V
4
AUX
5
6
F
1
F
2
FUEL
P
E
2
7
FL
2
GND
8
E
1
9
FL
1
Y
1
10
ROTOR
GND
+12 V
11
12
Voltage
(-)
(+)
250 mA fuse
Install fuse close to voltage source
Figure 25:
System voltage measurements. A 250 mA (or less) fuse is required
close to the system bus source.
9.3.2
Configuration
The table 12 shows correct channel settings.
Option
Selection/Setting
Channel
C only
Function
Voltage
Sensor
Voltage
Report time
0.5 – 1.0 s
Filter
1.0 s
Table 12:
Channel C configuration for system voltage.
9.4
Current
In order to measure electrical current a CT-30 sensor or a CT-60 sensor is
required. These sensors are produced by Kanardia. Standard shunts are not
supported.
CT-30 measures current between -30 and +30 A and CT-60 measures current
between -60 and +60 A. CT-30 is used for most applications.