Horis User Manual
2.7
Internal Backup Battery
Description
Value
Weight (eleccell)
32 g
Run-time (full brightness)
1.2 h
Charge time
3 h
Min charge voltage
12.0 V
Min charge temperature
0
◦
C
Max charge temperature
55
◦
C
Min operating temperature
-20
◦
C
Max operating temperature
70
◦
C
Table 8:
Horis backup battery module operating conditions.
chemistry is lower power density, so the total run-time is lower than
in competition instruments.
Description
Value
Type
LiFePO4
Capacity
850 mAh
Weight
21 g
Cell voltage
3.2 V
Table 9:
Internal backup battery cell specification.
2.7.2
Operation
Horis with internal battery is able to start even when external power
is not present. It is started with a short press on rotating knob. Horis
will start only when battery charge is sufficient.
When external power is applied to Horis it will start just like normal
Horis. When external power is switched off, Horis remains powered
29
©
Kanardia
2021
Содержание Horis
Страница 2: ......