Installation & operation guide
Kamstrup A/S • 55122662_C1_US_06.2020
5
READy MTU
Read the guide prior to installation and taking the device into use.
The product may only be installed by trained personnel.
Wire terminations must be properly sealed with a non-conductive gel material to prevent water intrusion
(otherwise, this configuration should not be used in a pit environment).
Kamstrup does not recommend using gel connectors in pit environments.
Kamstrup recommends mounting READy MTU in/under non-metallic meter pit lids only. If installing under metal
lids, make sure to use the pit antenna.
Mount READy MTU as high as possible in the pit, without the antenna being in contact with the pit lid.
Mount READy MTU as high as possible. The MTU should be mounted at or above ground level. Mount READy MTU
as high as possible. The MTU should be mounted at or above ground level.
Always install READy MTU in the protection cover (accessory) when the device is installed in sun-exposed areas.
Mount READy MTU at least 6 inches away from any metal objects, including pipes, conduit, and downspouts.
When mounting multiple MTUs in the same location, leave at least 4 inches between the MTUs if mounting side
by side and at least 3 inches between MTUs if mounting one above another.
Do not mount READy MTU so that it is transmitting towards a nearby building or fence.
Do not mount READy MTU directly under AC power or telecommunications wires.
Mount READy MTU as high as possible near an exterior wall. The MTU should be mounted at or above grade
(ground level).
Mount READy MTU at least 6 inches away from pipes and conduit and several inches below the ceiling.
Mount READy MTU at least 5 feet away from any large metal objects. (e.g. refrigerators, HVAC ducts, furnaces,
and hot water heaters).
Do not mount READy MTU in a basement with a metal ceiling.
Do not mount READy MTU directly under AC power wires, circuit breaker panels, or telecommunications wires.