12
Kamstrup A/S • 55121351_D2_GB_04.2015
MULTICAL® 302
9 Setup Mode
Setup
When delivered, the meter is in transport state,
which means that the display loop "Setup" is
available.
The Setup loop is selected by activating the button
continuously for 9 secs. until "SETUP" is displayed.
The meter remains in Setup loop until the front
button is pressed for 5 secs. However, a time-
out secures that the meter reverts from Setup
mode to normal mode after 4 minutes.
The readings of Setup loop are listed below including index numbers:
Setup loop (Loop_3)
Index number
in display
1.0
Customer number (No. 1)
3-01
2.0
Customer number (No. 2)
3-02
3.0
Date
3-03
4.0
Hour
3-04
5.0
Target date (MM.DD)
3-05
6.0
Flow sensor in: Inlet or Outlet (code A)
3-06
7.0
Measuring unit and resolution (code B)
3-07
8.0
M-Bus primary address (No. 31)
3-08
9.0
Average time of max P and Q
3-09
10.0
hc
(can only be changed with country code 6xx. Other country codes show
180 °C without the changing option)
3-10
11.0
Radio "ON" or "OFF"
3-11
12.0
End setup
3-12
After 4 minutes without activation of the button, the meter reverts to energy reading in the User
loop.