1  Mounting

Typically, the module is supplied mounted 
directly in RF Concentrator or similar 
equipment.

Example of mounting in RF Concentrator

2  Connection

The IP module has no built-in encryption, and therefore it should always be placed behind a firewall 
or NAT (Network Address Translation).

3  Configuration

The IP201 module is always supplied configured with either default IP settings or custom IP 
settings. These settings can be changed subsequently by using 

IP Tool

, which can be obtained by 

contacting Kamstrup. 
It is possible to use either dynamic or static IP addresses, and it is possible to order with the 
following settings:

Dynamic IP address (DCHP):

Host server name 

(the DNS name or IP address of the server to which the unit must report back)

.

Static IP address:

IP address, subnet, gateway 

(network settings of the module)

.

Host server 

(the IP address of the server to which the device must report back)

.

Содержание IP201

Страница 1: ...Installation guide IP201 Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com...

Страница 2: ...ts 1 Montage 3 2 Anschluss 3 3 Konfiguration 3 4 Ethernet Anschluss 4 5 Installation 5 6 Platzierung von Leuchtdioden Ausschnitt des Moduls 6 7 Status Leuchtdioden 6 7 1 Action 6 7 2 Wink 6 7 3 Err 6...

Страница 3: ...ways supplied configured with either default IP settings or custom IP settings These settings can be changed subsequently by using IPTool which can be obtained by contacting Kamstrup It is possible to...

Страница 4: ...nal MCU 114 116 Orange White Ethernet Tx RE4 RE5 115 117 Orange Ethernet Tx RE6 RE7 116 114 Green White Ethernet Rx RG5 117 115 Green Ethernet Rx RG4 Termnial number Silk screen print on 5550844 rev G...

Страница 5: ...s established connection to the network valid IP 3 The Err diode starts flashing when the host is recognised meter or concentrator have been detected 4 The Err diode turns off when the module has been...

Страница 6: ...ork the faster the flashing the more traffic Steady light The module is connected but there is no traffic on the network 7 2 Wink The Wink diode is used for indicating the module s conditions in three...

Страница 7: ...Port B Port B is a serial RS232 Kamstrup 3 wire connection that can be used for connecting additional external equipment For instance Connection of additional RF concentrator Port B is always configu...

Страница 8: ...Kamstrup A S 5512937_C1_GB_05 2017...

Отзывы: