User manual
wM-Bus Dongle SW Tool
Appendix E:
OMS T2 meter set-up
5512-1
057
GB /
12.2011 /
A1
Figure 13
If the option board (radio module) in the meter is an OMS T2 type, the set-up should be as follows:
•
Transfer the data from the
Main
tab, or enter the
METER ADDRESS
manually.
•
Set the options as shown, i.e. tick the checkboxes
Meter enabled
,
2-way radio
,
OMS T2 protocol
and
Meter data valid
(
Options in hex
= 4B).
•
Set
Meter install state
to 1 as there is no installation procedure.
•
Set
T1 period (in seconds)
to how often the meter is to send out meter data.
T2 fraction
is not
used.
•
Enter the same key in
IEK
and
KEY
.
•
Rev B barcode
is not used.
•
For the
Option Board
data fields, see
.
No Encryption on M-Bus:
•
Tick this checkbox if the decryption has to be done in the back office (then the
Options in HEX
will show 43).
Important for OMS: Both
IEK
and
KEY
must be set, and set to the same key.
16