24
1.57
TIP unit heaters
Unit heaters with 2-stage three-phase motor / Unit heaters with 1-stage single-phase motor
Installation and operating instructions
14. Declaration of Conformity
H
e
a
t
n
g
c
a
p
a
ci
ty
W
ä
rm
e
le
is
tu
n
g
To
ta
l
e
le
ct
ri
c
p
o
w
e
r
in
p
u
t
E
le
kt
ri
sc
h
e
G
e
sa
m
tl
e
is
tu
n
g
sa
u
fn
a
h
m
e
Version
Series
Serie
kW
kW
kW
kW
dB (A)
Serie 54
-
-
5,6
0,170
71
Serie 55
-
-
8,8
0,300
75
Serie 56
-
-
13,7
0,360
74
Serie 57
-
-
21,2
0,740
77
Serie 54
-
-
7,1
0,170
71
Serie 55
-
-
12,2
0,300
75
Serie 56
-
-
18,6
0,360
74
Serie 57
-
-
28,6
0,740
77
Serie 54
-
-
8,0
0,170
71
Serie 55
-
-
13,7
0,300
75
Serie 56
-
-
21,3
0,360
74
Serie 57
-
-
34,3
0,740
77
Serie 54
-
-
5,6
0,100
71
Serie 55
-
-
8,8
0,260
75
Serie 56
-
-
13,7
0,360
74
Serie 57
-
-
21,2
0,530
77
Serie 54
-
-
7,1
0,100
71
Serie 55
-
-
12,2
0,260
75
Serie 56
-
-
18,6
0,360
74
Serie 57
-
-
28,6
0,530
77
Serie 54
-
-
8,0
0,100
71
Serie 55
-
-
13,7
0,260
75
Serie 56
-
-
21,3
0,360
74
Serie 57
-
-
34,3
0,530
77
Standard ratng conditons for fan coil units according to regulaton (EU) No 2016/2281
Norm-Prüfbedingungen für Gebläsekonvektoren gemäß Verordnung (EU) Nr. 2016/2281
Cooling Test /
Inlet water temperature
7 °C
Water temperature rise
5 °C
Test Kühlbetrieb
Luft-temperatur
Heatng Test
20 °C (dry bulb)
Inlet water temperature
Test Heizbetrieb
Luft-temperatur
20 °C (Trockenkugel)
Sound power test
At ambient conditons without water flow
Test Schallleistungspegel
Bei Umgebungsbedingungen ohne Wasserdurchsatz
Contact Details
Kampmann GmbH
Kontaktinformationen
Friedrich-Ebert-Straße 128-130, D-49811 Lingen (Ems), Germany
Informaton requirements for fan coils according to regulaton (EU) No 2016/2281
Informationsanforderungen für Fan Coils gemäß Verordnung (EU) Nr. 2016/2281
TIP
heatng only
nur heizen
2-pipe unit
2-Rohrsystem
co
o
li
n
g
c
a
p
a
ci
ty
(s
e
n
si
b
le
)
K
ü
h
lle
is
tu
n
g
(s
e
n
si
b
e
l)
co
o
li
n
g
c
a
p
a
ci
ty
(l
a
te
n
t)
K
ü
h
lle
is
tu
n
g
(l
a
te
n
t)
S
o
u
n
d
p
o
w
e
r
le
ve
l
(p
e
r
sp
e
e
d
s
e
t
n
g
,
if
a
p
p
li
ca
b
le
)
Sc
h
a
lll
e
is
tu
n
g
sp
e
g
e
l
(g
g
f.
j
e
G
e
sc
h
w
in
d
ig
ke
it
s-
e
in
st
e
llu
n
g
)
heat exchanger
Wärmetauscher
P
rated,c
P
rated,c
P
rated,h
P
elec
L
WA
AC 230V
Fan code no. 31
Motorkennziffer 31
low, code no. 20
niedrig, Kennziffer 20
medium, code no. 30
mittel, Kennziffer 30
high, code no. 40
Hoch, Kennziffer 40
AC 400V
Fan code no. 36
Motorkennziffer 36
low, code no. 20
niedrig, Kennziffer 20
medium, code no. 30
mittel, Kennziffer 30
high, code no. 40
Hoch, Kennziffer 40
Air
temperature
27 °C (dry bulb)
19 °C (wet bulb)
27 °C (Trockenkugel)
19 °C (Feuchtkugel)
Wassertemperatur am
Einlass
Anstieg der
Wassertemperatur
Air
temperature
45 °C for 2-pipe units
65 °C for 4-pipe units
Water temperature
decrease
5 °C for 2-pipe units
10 °C for 4-pipe units
Wassertemperatur am
Einlass
45 °C für 2-Rohrsysteme
65 °C für 4-Rohrsysteme
Sinken der
Wassertemperatur
5 °C für 2-Rohrsysteme
10 °C für 4-Rohrsysteme
Содержание TIP 54 Series
Страница 27: ......