Assembly, installation and operating instructions

22

6.5.2 Overview of valve kits

Valve kits

Pre-adjustable thermostatic
valve

2-pipe, includes pre-set-
table valve, angled return
shut-off valve, with 2x
stainless steel corrugated
pipes, 1/2” connection on
left, KVS value 1.7 m³/h

PowerKon LT, DN 15

129012100201

2-pipe, includes pre-set-
table valve, angled return
shut-off valve, with 2x
stainless steel corrugated
pipes, 1/2” connection on
right, KVS value 1.7 m³/h

PowerKon LT, DN 15

129012200201

Differential pressure-inde-
pendent thermostatic valve

2-pipe, includes pre-set-
table valve, angled return
shut-off valve, with 2x
stainless steel corrugated
pipes, 1/2” connection on
left

PowerKon LT, cooling flow
volume (min./max.) 35 –
420 l/h, DN 15

129012100202

2-pipe, includes pre-set-
table valve, angled return
shut-off valve, with 2x
stainless steel corrugated
pipes, 1/2” connection on
right

PowerKon LT, cooling flow
volume (min./max.) 35 –
420 l/h, DN 15

129012200202

Valve kit, LHS connection

Valve kit, RHS connection

Содержание PowerKon LT

Страница 1: ...PowerKon LT Assembly installation and operating instructions Keep these instructions in a safe place for future use Issue07 23EN SAP No 1816160...

Страница 2: ......

Страница 3: ...ruction and function 13 5 1 Overview 13 5 2 Brief description 13 5 3 Wear parts list 13 6 Installation and wiring 14 6 1 Definition of the connection side 14 6 2 Requirements governing the installatio...

Страница 4: ...nance 42 10 1 Securing against reconnection 42 10 2 Maintenance Schedule 42 10 3 Maintenance work 43 10 3 1 Clean the inside of the unit 43 10 3 2 Replacing the filter 43 10 3 3 Cleaning the condensat...

Страница 5: ...lations apply as do general safety provisions governing the use of the equipment Illustrations in this guide are intended to provide a basic understanding and may differ from the actual model Ongoing...

Страница 6: ...ower net work The operating limits and limits of use described in Chapter 2 2 6 must be observed Intended use of the unit also includes adherence to these instructions Information in accordance with E...

Страница 7: ...would refer to VDI 2035 Sheets 1 2 DIN EN 14336 and DIN EN 14868 with regard to the properties of the medium used to protect the equipment The following values provide further guidance The water used...

Страница 8: ...as switch cabinets computers or other electrical units or contacts that are not drip proof Never use the unit as a construction site heater Never operate the unit in areas with a high dust content IM...

Страница 9: ...gained from specialist professional training Safety and accident prevention regulations Guidelines and recognised technical regulations i e Association of German Electricians VDE regulations DIN and...

Страница 10: ...nn website IMPORTANT NOTE 2 people are needed to transport the unit Wear personal protective clothing when transporting the unit Only lift the unit on both sides and not by the pipes valves IMPORTANT...

Страница 11: ...l vibrations and shocks IMPORTANT NOTE Under certain circumstances packages can carry storage instructions that exceed the requirements listed here Comply with these instructions accordingly 3 4 Packa...

Страница 12: ...t of basic unit kg 17 19 7 21 8 Air volume flow m h 110 246 160 369 189 502 Power consumption W 7 3 19 5 11 0 33 0 13 7 34 8 Water content l 0 8 1 2 1 5 Heat output W 9 784 1429 1171 2215 1450 2850 Co...

Страница 13: ...ical junction box 5 2 Brief description PowerKon LT are fan assisted and wall mounted convectors heaters for heating and cooling The units silently air condition rooms and their multiple connection op...

Страница 14: ...he installation site Only install and assemble the unit if the following conditions are met Ensure that the unit is securely suspended Ensure that the airflow can circulate freely Provide adequate spa...

Страница 15: ...on LT minimum clearances This area needs to be kept as free as possible to ensure that the air can flow freely out of the air outlet grille Window sills should be a minimum of 10 cm from the air outle...

Страница 16: ...RTANT NOTE Horizontal installation of units When installing the units ensure that they are completely horizontal to ensure proper operation IMPORTANT NOTE Avoid draughts Consider the occupied zone whe...

Страница 17: ...PowerKon LT PowerKon LT Assembly installation and operating instructions 17 6 4 1 Installing the unit...

Страница 18: ...PowerKon LT PowerKon LT Assembly installation and operating instructions 18 780 1030 1220 141 618 Fig 4 PowerKon LT dimensions...

Страница 19: ...oosen the thermostatic valve and return shut off valve Remove the heater and dismantle the existing fitting from the wall Position the fixing rail for PowerKon LT level and fix in place Prepare the ex...

Страница 20: ...erKon LT 6 5 Installation Actuator with First Open function When delivered the actuator is normally open in a de energised state thanks to the First Open function This enables heating mode to run even...

Страница 21: ...here is a danger to the user from cold temperatures and a danger to the environment from the use of glycol Put in place appropriate safety measures Remove protective caps from the supply and return Wi...

Страница 22: ...nless steel corrugated pipes 1 2 connection on right KVS value 1 7 m h PowerKon LT DN 15 129012200201 Differential pressure inde pendent thermostatic valve 2 pipe includes pre set table valve angled r...

Страница 23: ...n nection supplied separately All models connection on left 129013100000 Cooling accessory kit Accessory kit for cooling with condensate for con densate drainage with a natural gradient consisting of...

Страница 24: ...contact is triggered to prevent the condensate tray from overflowing Condensate drain Ensure that drainage of condensate from the condensate pump runs along a natural gradient with an adequate cross s...

Страница 25: ...separately 1290131100 00 Condensate pump set sup plied separately Condensate pump for cooling below the dew point for the discharge of condensate pro duced 50 60 Hz consisting of valve con densate tr...

Страница 26: ...h automatic universal power input detection Output 8 W at maximum operation at 110 V Alarm relay 7 amp contacts with integrated replaceable 6 3 A fuse 5 20 mm Weight 1 000 g 2 2 lb Discharge star pipe...

Страница 27: ...de Or LED displays in operation The pump features 3 extra long running cycles and reconfigures the DIP switches for more capacity Red The pump cannot keep up with the water feed To prevent the water f...

Страница 28: ...ectrical rating values PowerKon LT 7 2 Electromechanical connection 230 V 00 Circuit description 00 Factory fitted actuators are wired to the terminals The appropriate terminals are available for valv...

Страница 29: ...tive type F For the design of the rated residual current the specifications from DIN VDE 0100 Parts 400 and 500 must be observed For the design of the on site mains supply and fuse protection C16A max...

Страница 30: ...site Observe the Electrical data table Main supply 230V PowerKon LT Electromechanical Unit no 1 Building Automation BA Valve actuator Open Close Unit 2 Valve actuator Open Close Unit 1 Speed unit No 2...

Страница 31: ...ction on site Observe the Electrical data table Main supply 230V 1 2 gn ge gn ge 1 L N PE GND Uc VHi 1 2 3 4 Ri 100 K 4 2 3 3 W1 3 W2 1 2 2 5 4 3 2 1 GND VH Uc 24V DI 4 3 Room thermostat Type 342924 2...

Страница 32: ...e g Heat Cool Contact e g window Climate controller Type 30155 optional More information see Instruction Climate controller L N PE GND Uc VHi 1 2 3 4 Ri 100 K N PE L 1 2 gn ge Main supply 230V Fuse pr...

Страница 33: ...at Optionally 3 level fan stages can be selected using a rocker switch Fig 8 Control curves IV DIP 1 0 DIP 2 1 max 8 V at stage 3 DIP1 DIP2 Factory setting DIP switch function 0 0 Test mode 1 0 Switch...

Страница 34: ...nection cable with a standard European plug 1 Power supply 230 V 2 Condensate pump power supply 230 V 3 Valve drive s 230 V Open Closed 4 Heat pump contact On Off potential free 5 Heat pump contact he...

Страница 35: ...ntly on ON 6 Heating fan operation Thermostatic control Permanently on ON 7 Fan switch off delay No delay 3 minutes ON 8 Master slave Master Slave OFF Tab 10 DIP switch Jumper Function Open Closed Sta...

Страница 36: ...tive type F For the design of the rated residual current the specifications from DIN VDE 0100 Parts 400 and 500 must be observed For the design of the on site mains supply and fuse protection C16A max...

Страница 37: ...2 3 DI2 Heat pumps heating cooling DI3 4 5 RS485 1 RS485 2 1 3 2 1 2 3 Twisted Pair Main supply 230V Fuse protection on site Observe the Electrical data table HP On OFF HP H C 1 2 3 4 5 5 W1 DI1 HP O...

Страница 38: ...et in accordance with the wiring diagram Water side checks Check whether all supply and drainage lines have been properly connected Fill pipes and unit with water and bleed Check whether all bleed scr...

Страница 39: ...n Automatic fan 3 stage switch for pre selecting the fan speed when the operating mode selector switch is in the Manual fan position option for external room sensor connection control input for heatin...

Страница 40: ...low temperature T2 is not reached Lit red Heating mode Lit blue Cooling mode The following messages appear on the display in the event of an alarm Message Flash code Meaning Unit status AL1 1x flashin...

Страница 41: ...999 2 0 1 Off display is automatically switched off 30 seconds after the last operation 2 Password 022 Extended parameters Parameter Description Setting Standard F rt Filter run time RO F rS Filter re...

Страница 42: ...nd teat Contact the manufacturer with any questions about maintenance work and intervals Interval Maintenance task Personnel As required Regular visual checks and acoustic checks for damage dirt and f...

Страница 43: ...rt or deposits dur ing maintenance and use a commercially available product to remove Remove the casing upwards When refitting make sure that the side recesses are sitting correctly on the wall bracke...

Страница 44: ...n LT PowerKon LT Assembly installation and operating instructions 44 10 3 3 Cleaning the condensate tray Clean the condensate tray 10 3 4 Cleaning the valve condensation tray Clean the valve condensat...

Страница 45: ...ormation Behaviour in the event of faults The following applies 1 Immediately switch off the unit with faults that pose an immediate danger to persons or property 2 Determine the cause of the fault 3...

Страница 46: ...nit system Valves not operating Replace faulty valves Water volume too low Check pump output check hydraulics Setpoint temperature on the controller set too low high Adjust temperature setting on the...

Страница 47: ...article Typ Model Nr artyku u Typ Model slo v robku auf das sich diese Erkl rung bezieht mit der den folgenden Norm en oder normativen Dokumenten bereinstimmt to which this declaration relates is in c...

Страница 48: ...2009 125 EG ErP Richtlinie 2016 2281 EU Durchf hrungsverordnung f r Luftheizungsprodukte K hlungsprodukte Prozessk hler mit hoher Betriebstemperatur und Gebl sekonvektoren Frank Bolkenius Lingen Ems...

Страница 49: ...45 C for 2 pipe units 65 C for 4 pipe units Water temperature decrease 5 C for 2 pipe units 10 C for 4 pipe units 20 C Trockenkugel Wassertemperatur am Einlass 45 C f r 2 Rohrsysteme 65 C f r 4 Rohrs...

Страница 50: ...Tab 2 Operating voltage 7 Tab 3 Water quality 7 Tab 4 Technical data 12 Tab 5 Condensate accessories 25 Tab 6 Technical data for condensate pump 26 Tab 7 Maximum electrical rating values 28 Tab 8 DIP...

Страница 51: ......

Страница 52: ...ac products fan coils powerkon lt Country Contact Great Britain Kampmann UK Ltd Dial House Govett Avenue Shepperton Middlesex TW17 8AG T 44 1932 228592 F 44 1932 228949 E info kampmann co uk W Kampman...

Отзывы: