Encased convectors

Encased models with                 heat exchangers

Installation manual

1.26

1.46

1. Correct and proper use 

Kampmann Po F encased convectors have been
designed and manufactured in accordance with state-of-the-art
engineering and recognised safety regulations. There is
nevertheless a risk to persons and property, including damage to
the equipment itself, if the equipment is not fitted, operated
and used properly.

Po F encased convectors should only be used indoors,
that is to say, in private property,  offices and exhibition rooms for
example. This equipment is not suitable for use in damp areas,
such as swimming pools or outdoors. The equipment should be
prevented from becoming wet during installation. If in doubt
please contact the manufacturer. Any use not mentioned above
will be deemed to be incorrect and improper and any damage
resulting from this will be the sole responsibility of the
operator/user of the equipment. Correct and proper use is also
deemed to include adherence to the installation instructions
included in this manual.

The installation of this equipment requires some technical skill
and expertise in the field of heating, cooling and ventilation.
This knowledge is generally gained in vocational training in
heating, cooling and ventilation and is not described in detail
here. Any damage resulting from improper installation is the
sole responsibiltiy of the user/operator of the equipment.

2. Safety instructions

The fitting, installation and servicing of electrical equipment
should only be carried out by a qualified electrician in
accordance with VDE (Association of German Electricians’)
regulations. The equipment should be wired in accordance with
current VDE electrical regulations and EVU guidelines.

Non-compliance wih the directives can lead to malfunction of
the equipment and possible damage and risk to persons and
property. There is a risk of fatal injury if the equipment is wired
incorrectly and wired are crossed!

All parts of the system should be disconnected from the mains-
before installation work or servicing is carried out and should be
prevented from being switched on again acccidentally.

Содержание Powerkon + F

Страница 1: ...anual 1 26 1 26 Contents Seite 1 Correct and proper use 2 2 Safety instructions 2 3 Inventory 3 4 Fitting encased convectors on finished floors 4 5 Fitting encased convectors on unfinished floors 5 6...

Страница 2: ...o deemed to include adherence to the installation instructions included in this manual The installation of this equipment requires some technical skill and expertise in the field of heating cooling an...

Страница 3: ...t exchanger 2 with 1 no air vent 3 supplied loose Brackets the number supplied depends on the length of the casing and the model ordered i e for finished floor 4 or for unfinished floor 5 or wall moun...

Страница 4: ...ger with the brackets fitted onto the floor where it is to be installed and mark the drill holes Fix the brackets using screws and rawl plugs by others 7onto the floor and level the unit Connect up th...

Страница 5: ...anger pipes fit into the recesses in the support plates Place the heat exchanger with the brackets fitted onto the floor where it is to be installed and mark the drill holes Fix the brackets using scr...

Страница 6: ...If there is a central bracket units over 1600mm in length fit it in such a way that the heat exchanger pipes fit into the recesses on the support plate Connect up the flow 8and return 9 pipework The...

Страница 7: ...nn valve set type 126102 optional accessory encased convector fitted on a finished floor is illustrated 1 1 2 flow 2 1 2 return 3 air vent 4 1 2 thermostatic valve body on flow 5 thermostatic valve he...

Страница 8: ...depth mm Casing height 80 mm Casing height 130 mm 130 180 230 2 1 2 1 2 1 2 1 2 1 2 1 Encased convector shown with finished floor brackets 1 1 2 flow 2 1 2 return Encased convectors Encased models wit...

Отзывы: