background image

1. Master/Slave operaton 

You can link multiple units together in Master/Slave mode. To achieve this you will need to set the first unit in the chain as the 

Master 

unit and then set all other linked units as 

Slave 

units. 

 

Using DMX cables, link the units from the DMX output of the first (

Master

) unit to the DMX input of the second (

Slave

) unit, then 

link the DMX output of the second unit to the DMX input of the third unit and so on. 
 
Next set the first unit to be the 

Master

:  

 
1.

 

Press the 

Menu

 button and choose 

SLnd

 

2.

 

Press the 

Enter 

button 

3.

 

Set the unit to 

NASt

 

4.

 

Press the 

Enter 

button to confirm your choice 

5.

 

Next set the unit to Show mode 

Shnd

 (and choose a show (0-16) 

 

Next set the other units to be 

Slave mode

:  

 
6.

 

Press the 

Menu

 button and choose 

SLnd

 

7.

 

Press the 

Enter 

button 

8.

 

Set the units to 

SL1 

(normal Slave mode) or 

SL2

 (dual light show mode) 

9.

 

Press the 

Enter 

button to confirm your choice 

 
All unit should now operate in Master/Slave mode where all units operate the same show as the first unit in the chain. If you are 
only joining two units in Master/Slave mode, it is reccomended to us 

SL2 

Slave mode. 

 

2. DMX controller operation 

If you intend to operate the unit using a DMX controller, then you need to begin by setting the address. Choose A001 as the 
default address. Below are the DMX channel function tables for each DMX mode. 
 

6 channel DMX mode 
 

Channel 

Value 

Function 

000-255 

Full dimmer 0 - 100%

 

000-255 

Strobe, slow to fast

 

000-007 

No function

 

008-022 

Show 1 

023-037 

Show 2 

038-052 

Show 3 

053-067 

Show 4 

068-082 

Show 5 

083-097 

Show 6 

098-112 

Show 7

 

113-127 

Show 8 

128-142 

Show 9 

143-157 

Show 10 

158-172 

Show 11 

173-187 

Show 12 

188-202 

Show 13 

203-217 

Show 14 

218-232 

Show 15 

233-247 

Show 16 

248-255 

Sound-to-Light mode 

000-255 

Show mode speed adjustment, slow to fast 

000-014 

Static LED colour change Show 

015-255 

Colour chase 

000-255 

Colour chase, slow to fast 

Содержание VECTOR6

Страница 1: ...le Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a rec...

Страница 2: ...The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to...

Страница 3: ...ad rigging required extensive experience Working load limits should be respected certified installation materials should be used the installed unit should be inspected regularly for safety l Make sure...

Страница 4: ...LED Function menu...

Страница 5: ...the Menu button to return to the main menu or wait 10 seconds and this will happen automatically 7 LED display setting Led Select Led in the Function Menu and press the Enter button to confirm Using t...

Страница 6: ...mode 9 Press the Enter button to confirm your choice All unit should now operate in Master Slave mode where all units operate the same show as the first unit in the chain If you are only joining two u...

Страница 7: ...73 Blue white 174 189 Red green blue 190 206 Red green white 207 222 Red blue white 223 239 Green blue white 240 255 Red green blue white 3 5 000 255 Second head Y axis position 4 6 000 255 Second hea...

Страница 8: ...00 255 First head Y axis fine position 5 000 255 First head speed fast to slow 6 000 255 First head colour 7 000 255 Second head Y axis position 8 000 255 Second head Y axis fine position 9 000 255 Se...

Отзывы: