DMX-512 connection
Overhead Rigging
Make sure the area below the installation place is free from unwanted persons during rigging, de-
rigging and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids.
The fixture must be fixed at least 50cm from surrounding walls
The device should be installed out of reach of people and outside areas where persons may walk
by or be seated.
The device should be well fixed; a free swinging mounting is dangerous and may not be
considered!
Do not cover any ventilation opening as this may result in overheating
Before the first time use, it must be inspected by professional staff to make sure safety, inspection
regularly every year.
◆
◆
◆
◆
◆
◆
Attention!
The installation must be carried out by qualified service personal only. Improper installation can
result in serious injuries and /or damage to property. Overhead rigging required extensive
experience! Working load limits should be respected, Certified installation materials should be
used, the installed device should be inspected regularly for safety.
Overhead Rigging
3
AC Power
Please use the attached power cord, note that power voltage and frequency
are the same as the marked voltage and frequency of device when
connecting power. Every device’s power should be connected separately,
so that device can be controlled individually.
Cable spec.
Cable(EU)
Brown
Light blue
Yellow/Green
Cable(US)
Black
White
Yellow/Green
Pin
Live
Neutral
Earth
International
L
N
Connection between lights and DMX must use the shielded cable of diameter more than 0.5mm.
Please use the attached 3 pin XLR plug/socket to connect the DMX output/input interface. The
connection between socket and cable as below (note the plug/socket’s 3 pin number and position).
Note, XLR plug/socket’s 3pin can not be touched by inner hull, connection between pins is not allowed.
Except above connection, XLR plug/socket can not be connected with XLR control line. Device receives
international standard DMX512(1990) control signal.
When using standard DMX512 control signal, the last device’s output interface must be
connected to a DMX plug. This plug is putting a 120 ohm resistance between “canon”
plug’s 2 pin and 3 pin. Showing as below pic. Sticking this plug into the last device’s signal
output interface, it will avoid the interference during the process of signal transmission.
DMX
-
output
XLR mounting-sockets(rear view)
DMX
-
input
XLR mounting-plugs(rear view)
1-Shield
2-Shield(-)
3-)