Maintenance and cleaning
/ Boiler with cast iron brazier
The boiler requires a simple and thorough cleaning in order to
ensure a more effi cient performance and smooth operation.
While cleaning the inside of the boiler, to prevent the escape
of ashes, you can start the fan fl ue exhaust. To enable this
feature, you must press the button
and then .
The display shows “
P U L S T U F
” (cleaning boiler).
To stop the fan, simply press and hold the button or wait for
completion of a cleaning cycle (255 seconds).
Clean the grate using the appropriate tool from the ash and
any incrustation which could obstruct the passage of air. In
the case of depletion of pellets in the tank may accumulate
unburned pellets in the burn pot.
Always empty the residuals from the grate before each start.
Remember that only a brazier located and clean properly can
ensure ignition and optimal operation of your boiler. When
positioning the crucible, carefully check that the ends of the
pads completely adhere to their home and that the hole with
pipe dedicated to the passage of the resistance. There should
be no residual combustion in the contact zone between the
edges of the crucible and the support surface on the door
crucible.
BY THE USER
Daily control
Parts
Everyday
Every 2-3
days
Every
week
Every 15
days
Every 30
days
Every 60-
90 days
Every 1
year
Brazier
◊
Cleaning the ash collection
compartment with suction device
◊
Cleaning ash tray
◊
Exchanger (turbulators)
◊
Flame-shell
◊
Cleaning the interior heat exchanger /
smoke fan compartment
•
Cleaning complete exchanger
•
Clean "T" to exhaust
•
Flue
•
Door gasket ash
•
Internal parts
•
Flue pipe
•
Circulation pump
•
Heat exchanger (where present)
•
Hydraulic components
•
Electromechanical components
•
◊ by the user /
•
by the authorised qualifi ed technical assistance
All cleaning of all parts must be carried out with the Boiler completely cold and unplugged
to avoid burns and thermal shock. The boiler does not need much maintenance if used
with certifi ed quality pellet. The need for maintenance varies depending on the conditions
of use (switching on and off repeatedly) and depending on the performance required.
It is recommended periodic monitoring of the boiler to check its condition.