background image

INSTALLATION INSTRUCTIONS

  60" x 32" Acrylic Air Bath

1107630-2-

C

18 of 28

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.

INSTALL THE POWER CORD AT THE CONTROL - REMOTE (CONT.)

 

Connect a solid copper 8 gauge bonding wire from the bonding lug on the new junction box to the spare 
bonding lug on the control. Follow all local electrical codes.

Reconnect the Blower Motor Power Cord

 

If required, reconnect the blower motor power cord at the control.

 

Route the power cord through a strain relief on the new junction box. Tighten the strain relief.

 

At the end of the cut power cord, strip back the cable jacket about 3” (76 mm).

 

Cut the unused brown conductor off at the cable jacket and cap off with a wire nut.

 

Strip the wire insulation about 3/8” (10 mm) from the end of the wires.

Terminate the New Power Cable

 

Route the new power cable through the other strain relief on the new junction box. Tighten the strain relief.

 

Strip back the cable jacket about 3” (76 mm).

 

For installations in the United States, mark white conductors with red or black tape as required by the NEC.

 

Strip the end of the wires about 3/8” (10 mm).

 

Use approved termination devices to terminate the conductors as follows:

 

Connect the black pigtail lead to the L1 conductor of the power cable.

 

Connect the blue pigtail lead to the L2 conductor of the power cable.

 

Connect the green with yellow stripe pigtail lead to the grounding/earthing conductor of the power cable.

 

Install the cover on the new junction box.

12.  INSTALL THE PLUMBING - REMOTE

CAUTION: Risk of property damage.

 

A watertight seal must exist on all bath drain connections. The 

watertight seal will prevent property damage.

NOTE:

 To simplify future maintenance, provide access to all plumbing connections.

 

Loosely make connections between the bath and over

fl

 ow and the drain to the bath. Con

fi

 rm locations and 

adjust as needed.

 

Tighten connections between the bath and over

fl

 ow, drain to bath, and drain assembly to trap according to 

the drain manufacturer’s instructions.

 

Con

fi

 rm drain assembly connections are snug according to the drain manufacturer’s instructions.

 

Install the faucet valving according to the faucet manufacturer’s instructions. Do not install the faucet trim at 
this time.

 

Open the hot and cold water supplies. Check all connections for leaks.

 

Fill the bath to the over

fl

ow. Check the drain connections for leaks. Repair as needed.

Содержание P50047-G5

Страница 1: ...ONS 60 x 32 Acrylic Air Bath 1107630 2 C 1 of 28 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com P...

Страница 2: ...connections WARNING Risk of electric shock Disconnect power before servicing WARNING Risk of injury or property damage Please read all instructions thoroughly before beginning installation including t...

Страница 3: ...njury or damage caused by any such unauthorized modification Refer to the Before You Begin section for blower motor relocation requirements recommendations and section coverage information NOTICE Keep...

Страница 4: ...he Site 8 2 Install the Tiling In Bead optional 9 3 Prepare the Bath with Airjets 9 4 Secure the Bath to the Subfloor Standard 10 5 Install the Plumbing Standard 11 6 Make Power Connections Standard 1...

Страница 5: ...elocated The option is provided for the case that a particular installation makes this effort practical For your convenience or accessibility the blower motor and check valve can be mounted in a remot...

Страница 6: ...ce as specified in the Price Book TOOLS AND MATERIALS Plus Conventional woodworking tools and materials or conventional masonry tools and materials as appropriate Drop cloth Construction Adhesive opti...

Страница 7: ...PRODUCT INFORMATION Fixture Top Area Inside Area Weight Bathing Well 54 1 8 1375 mm x 25 15 16 659 mm 45 13 16 1164 mm x 24 3 4 629 mm 75 lbs 34 kg 00 100 lbs 45 4 kg G5 Water Depth Capacity To Overfl...

Страница 8: ...on the rim a 1 16 2 mm gap must exist between the framing and the underside of the rim When constructing the framing take into account the gap and the thickness of the finished wall deck material NOTI...

Страница 9: ...ows for an alcove installation of many drop in baths when a flanged version is not available NOTICE The bottom edge of the tiling in bead may have to be trimmed This will ensure a proper fit in the in...

Страница 10: ...ote Connect the Cable at the Blower Remote Install the Power Cord at the Control Remote Install the Plumbing Remote Make Power Connections Remote Then go to the Test Run the Bath with Airjets section...

Страница 11: ...d Apply a generous amount of high quality construction adhesive to the bottom of the support blocks With help carefully move the bath into the installation area Verify the support blocks are resting d...

Страница 12: ...Make sure the power has been disconnected before performing the following procedures Refer to the Important Information section WARNING Risk of electric shock Connect the control to a properly ground...

Страница 13: ...ve the retaining screw holding the air harness on the blower motor discharge Do not discard the screw at this time Remove the four blower motor mounting screws from the blower adapter baseboard Keep t...

Страница 14: ...tions NOTICE Ensure the subfloor is level before proceeding If necessary use shims to achieve level Cement or Mortar Bed Method NOTICE Do not use gypsum cement or drywall compound as these materials w...

Страница 15: ...or using four fasteners 2 51 mm Min Connect blower motor to the check valve use silicone or equivalent sealant and install retaining screw NOTE The blower motor must be mounted horizontally 2 51 mm ab...

Страница 16: ...E CABLE AT THE BLOWER REMOTE Cut existing cable about 4 102 mm from the blower motor Access Cover Strain Relief Blower Motor Plug Remove two screws to remove the cover Route the Power Cable Route two...

Страница 17: ...in relief Using wire nuts or other approved termination devices terminate the conductors as follows Connect the black pigtail lead to the L1 conductor of the power cable Connect the blue pigtail lead...

Страница 18: ...ck tape as required by the NEC Strip the end of the wires about 3 8 10 mm Use approved termination devices to terminate the conductors as follows Connect the black pigtail lead to the L1 conductor of...

Страница 19: ...bath Ensure that the control power supply cord is properly routed to the control power junction box The control power supply cord contains a brown wire Line 1 a blue wire Line 2 and a green wire with...

Страница 20: ...ections and make sure the electrical power to the bath is turned on Make sure all PVC piping connections are properly made Temporarily remove the protective drop cloth from the bath Ensure that the ar...

Страница 21: ...finished deck and the rim For Finished Wall Installations Cover the framing with water resistant wall material Apply a bead of silicone sealant in the groove between the edge of the bath deck and the...

Страница 22: ...n the bath The purge mode blows any residual water out of the air channels The blower motor starts and runs at a low speed for about two minutes An automatic purge cycle occurs when the bath is draine...

Страница 23: ...that cable ties or other clips support the air piping and electrical harnesses at the bath Ensure that any unused electrical connectors are supported above the floor Turn on power to the unit NOTE Tr...

Страница 24: ...of the surge mode Select and activate the surge mode Verify that the air flow cycles between minimum and maximum Increase or decrease the speed of the surge cycle by pressing the up or down button Tu...

Страница 25: ...FCI or Residual Current Device RCD trips when bath with airjets is turned on C Wiring harness from user keypad to control is loose disconnected or damaged C Check wiring for proper connections Replace...

Страница 26: ...er motor C Control does not work C Replace the control 5 Blower motor stops running and will not immediately restart Keypad is illuminated A Blower motor overheated and protection device activated A C...

Страница 27: ...ring harness B Check wiring for proper connections Replace the wiring harness if necessary C User keypad does not work C Replace the user keypad D Blower motor does not work D Replace the blower motor...

Страница 28: ...12 Water spillage or damage observed under the bath A Drain or overflow leaking A Repair or replace the drain assembly according to the manufacturer s instructions B Wall deck and or shower door is i...