INSTALLATION INSTRUCTIONS
Pressure Balance Trim
1491056-2-
A
4 of 14
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
1. WATER TEMPERATURE ADJUSTMENT
O-Ring
Setscrew
Tab
Tab
Collar
Collar
Setscrew
Valve Label
Standard Valve
High Flow Valve
Valve Stem
Valve Stem
CAUTION: Risk of personal injury.
The water temperature should never be set above 120° F (49° C).
NOTE:
Do not remove the O-ring and collar at this time. Removing the O-ring and collar will change the
factory setting for the maximum water temperature.
Discard the plaster guard.
Turn the valve clockwise to the full open position. After several minutes, check the temperature.
For
minor temperature changes
, adjust the setscrew and recheck the temperature.
For
major temperature changes
, remove the o-ring and the collar. Slowly turn the valve stem to adjust the
maximum water temperature.
Reinstall the collar with the setscrew against the tab. Reinstall the O-ring.
Recheck the temperature.
Turn the valve stem counterclockwise to the “OFF” position.
NOTE:
After adjustment, complete the required information on the valve label (if supplied).
2. DIVERTER ASSEMBLY (IF APPLICABLE)
Setscrew
Diverter Actuator
Valve Stem
Diverter Stem
Discard plaster guard with dome.
NOTE:
If the diverter stem has an E-clip and an O-ring, these must be removed before the actuator and
guide can be installed.
Position the actuator over the diverter stem. Secure with setscrew.