27
operations are tested. Following this, the fire is automatically set to ‘Off’ and remains in
this state until it is manually set to ‘On’.
8.1
Troubleshooting solutions or restarting after a malfunction
The burner control’s automatic settings depend on which type of gas is used: natural gas or
propane/butane. In the case of natural gas, the burner will make 3 automatic ignition
attempts, while in the case of propane/butane, it makes only 1 attempt. If ignition fails, the
error code A08 appears immediately and ‘ER’ (Error) displays at the top left of the screen.
Using the remote control, 2 more ignition attempts can be tried (or 1 attempt in the case of
propane/butane). If this new attempt also fails, the burner is automatically locked (error code
08F).