background image

VIBRATORY FINISHER SAFETY AND

OPERATING INSTRUCTIONS

READ THE OPERATING INSTRUCTIONS
BEFORE RUNNING MACHINE.

ALWAYS WEAR SAFETY GLASSES OR A
FULL FACE SHIELD FOR PROTECTION.

KEEP HANDS CLEAR FROM ALL
MOVING PARTS.

NEVER WEAR GLOVES OR LOOSE
FITTING CLOTHES WHEN OPERATING
THIS MACHINE.

ALWAYS KEEP HAIR TIED BACK OR
COVERED.

KEEP SAFETY GUARDS IN PLACE. DO
NOT ALTER GUARD OR MACHINE IN
ANY WAY. ANY ALTERNATIONS TO
GUARDS OR MACHINE COULD CAUSE
SERIOUS INJURY.

FOLLOW ALL INSTRUCTIONS
REGARDING COOLANT MIXTURE.

DISCONNECT POWER WHILE SERVICE
THE MACHINE.

MODEL KVF3 VIBRATORY FINISHER. 3.3 CUBIC FEET. TUB WEIGHT LIMIT 500 LBS.

SHIPPING LOCKS: LOCATED INSIDE TUBE ON EACH SIDE. REMOVE BEFORE
OPERATING UNIT.

FLEXIBLE COOLANT NOZZLE: DELIVERS COOLANT LUBRICATION TO MEDIA. KEEP
NOZZLE END CLEANED OUT FOR GOOD COOLANT FLOW.

VIBRATORY TUB- CAST URETHANE HOLDS MEDIA FOR: DEBURRING, POLISHING,
DRYING, etc. DRAIN PLUG IS LOCATED IN THE BOTTOM OF THE TUBE TO DRAIN
COOLANT INTO THE COOLANT TANK. USE THE CORRECT COOLANT FOR THE JOB
RECOMMENDED BY YOUR DEALER. MEDIA IS ALSO IMPORTANT DEPENDING ON THE
JOB AND RESULTS REQUIRED. BE CAREFUL WITH STEEL SHOT MEDIA NOT TO
OVERLOAD THE TUBE.

TIMER SWITCH TURNS ON/OFF 115V VOLT AC POWER TO UNIT.

DISCHARGE CHUTE- ALLOWS FOR EASY N-LOADING OF MEDIA INTO A BUCKET. UN-
SCREW LOCKING KNOB AND REMOVE URETHANE PLUG. PLACE A BUCKET UNDER
THE CHUTE AND TURN ON THE UNIT TO ALLOW THE MEDIA TO VIBRATE INTO THE
BUCKET. YOU CAN UN-LOAD PARTS ALSO AT THE SAME TIME BUT IT’S BETTER TO
UN-LOAD PARTS

BEFORE

REMOVING THE MEDIA. REPLACE URETHANE PLUG AND

LOCKING KNOB/BAR TIGHTLY BEFORE USING UNIT AGAIN.

LUBRICATION POINTS- LUBRICATE AFTER EVERY 8 HOURS OF USE WITH GREASE
INTO THE BEARING ZERK FITTINGS LOCATED THROUGH THE ACCESS HOLES IN THE
BACK OF THE UNIT.

TURN OFF UNIT BEFORE LUBRICATING. CAUTION- DO NOT

REMOVE UNIT TOP COVER DANGEROUS ROTATING COUNTER WEIGHT CAN
CAUSE SERIOUS INJURY.

COOLANT PUMP/COOLANT TANK- DELIVERS COOLANT TO THE VIBRATING TUB.

KEEP COOLANT TANK CLEAN!

MEDIA WILL DEGRADE AND BREAK DOWN AND

COLLECT IN THE COOLANT TANK.

WITH POWER OFF

REMOVE THE PUMP FROM THE

TANK, SLIDE OUT THE TANK AND CLEAN OUT. REPLACE THE PUMP INTO THE TANK
AND SLIDE THE TANK UNDER THE UNIT BEFORE OPERATING.

Отзывы: