64
Error code Cause
Solution
02F
The temperature of
the printed circuit
board is too high.
Switch off the fire for around 30 minutes. Then
turn it back on. If the error code displays again, this
indicates that the ventilation in the hearth of the
fire is insufficient. Contact your installer.
06E
or
is flashing
Communication
failure between the
remote control and
the fire
If the indicator light on the burner control (in the
technical unit) is not flashing:
Check the voltage in your home. If the voltage is
correct, you should contact your installer in order
to detect a possible fault in the 24V transformer or
the burner control.
If the indicator light on the burner control (in the
technical unit) is flashing:
Bring the remote control as close as possible to the
fire and press
. Wait for about 60 seconds. If the
light continues to flash, resynchronise the remote
control and the technical unit (see error code
‘
NOLK
’).