When your Fridge/Freezer is first connected
to the AC or DC power input the appliance
will automatically switch on and the LCD
control panel will display the current cabinet
temperature, battery monitor and Eco setting
as well as the current input voltage.
The Temperature Controller provides the
ability to set the desired temperature level and
display the current cabinet temperature. The
electronic controller has been programmed to
maintain an average of the set temperature.
The compressor will start up when the internal
cabinet temperature increases 3F to 4F
degrees above the set temperature and will
run until the temperature is 3F to 4F degrees
below the set temperature.
BATTERY DISPLAY
Voltage is measured at the input connection on
the side of the appliance.
Battery Display
12V
24V
9.6V or less
21.3V or less
9.7V to 10.3V
21.4V to 22.4V
10.6V to 11.0V
22.7V to 23.5V
11.1V to 11.7V
23.6V to 24.6V
11.8V to 12.4V
23.7V to 25.7V
12.5V or above
25.8V or above
*Values are for reference only and may be subject to
change depending on conditions and power supply.