Measurement operation
AC current measurement
The current is measured via the current clamp (1). The sensors in the current clamp detect the
magnetic field created by current-carrying conductors. You can take measurements on insulated
and not insulated conductors.
The test leads should be disconnected from the measuring device when measuring current.
Proceed as follows to measure the current:
1) Estimate the current range (2 , 20 or 200 ) and turn the knob to 2 , 20 or 200 .
2) Press the clamp release lever and open the clamp.
3) Grasp the individual current conductor to be measured and close the current clamp again.
The measured conductor must be placed in the center of the clamp, otherwise additional errors
will occur.
4) The measured current is shown on the display. If current > 3A, the orange display lights up.