In high-sensitivity mode, the tester will be more sensitive and show voltage
indication at a further distance away from high voltage source than in
low-sensitivity mode.

Identify null and live wire

Keep the individual cables as far away from each other as possible and read
the signals.

The screen turns red and shows a high voltage symbol when the voltage is
higher than 90V. The neutral wire and live wire should not be distinguished

by the screen color, but by the detected signal intensity. The live wire causes
stronger signals and the neutral causes weaker signals.

It is recommended to activate the high sensitivity mode during identification.

Breakpoint testing

Activate the high sensitivity mode, move the tester's NCV tip
along the cable, the voltage alarm disappears when detected a
breakpoint, as shown in Figure 2.

Caution: Do not use it on cable ducts or metal-clad cables.

Live wire: Up to 8 bar charts

Fast beeps

Red screen

Null wire: Below 6 bar graphs

Slow beeps

Green screen

Содержание HT100B

Страница 1: ...o not put the device in more than 1000V This equipment can only be used indoors and should be protected from water high air humidity and heat ATTENTION Even without indication the voltage could still be present The voltage detector indicates the effective voltage when a supply voltage generates enough intensive electrostatic field If the field is very weak the voltage detector can t detect the exi...

Страница 2: ...e frequency of blinking and beeping becomes faster or slower with the signal intensity The signal intensity is affected by the distance from the voltage The further the tester is from the circuit the weaker the signal becomes Dual range When the tester is turned on it is in low sensitivity mode 48 1000V Briefly press the green button to enter the high sensitivity mode 12 1000V Refer to the followi...

Страница 3: ...re and live wire should not be distinguished by the screen color but by the detected signal intensity The live wire causes stronger signals and the neutral causes weaker signals It is recommended to activate the high sensitivity mode during identification Breakpoint testing Activate the high sensitivity mode move the tester s NCV tip along the cable the voltage alarm disappears when detected a bre...

Страница 4: ...tude 2000m Security level CE CAT III 1000V CAT IV 600V Batteries 2 1 5V AAA Battery replacement Rotate the battery cover off body remove the batteries and insert the positive terminal of the new battery toward the tip of the tester Rotate cap to the body until it is fully seated Before locking do not use the tester to test the electricity to avoid electric shock Cleaning Use only a soft slightly d...

Отзывы: