background image

1

Operation Manual

HT100B

Non-contact voltage tester

Please read this manual thoroughly before use and keep it for later

reference.

WARNINGS

With this device, life-threatening voltages are tested, so special
care is required!

Always first test the voltage tester on a known circuit to make
sure it works!

When checking uninsulated contacts, wear safety shoes to prevent
electric shock.

When checking uninsulated contacts, hold the tester and make sure

your fingers are behind the anti-slip guard.

Do not use the device if:

- The screen is not lit;
- Damage is evident;
- The tip is not intact.

Do not put the device in more than 1000V

This equipment can only be used indoors and should be protected from
water, high air humidity and heat.

ATTENTION

: Even without indication, the voltage could still be present.

The voltage detector indicates the effective voltage when a supply
voltage generates enough intensive electrostatic field. If the field is very
weak, the voltage detector can

t detect the existence of voltage.

We do not accept any liability for property damage or personal injury
caused by incorrect operation or failure to follow safety instructions. In
this case, any warranty claim will lapse.

Product Overview

1

Probe (NCV sensor)

2

Flashlight

3

Signal indicator

4

LCD screen

5

Power button(red)

6

S button (green)

Sensitivity (short press)

/

/LED lamp (long press)

7

Battery cover

Содержание HT100B

Страница 1: ...o not put the device in more than 1000V This equipment can only be used indoors and should be protected from water high air humidity and heat ATTENTION Even without indication the voltage could still be present The voltage detector indicates the effective voltage when a supply voltage generates enough intensive electrostatic field If the field is very weak the voltage detector can t detect the exi...

Страница 2: ...e frequency of blinking and beeping becomes faster or slower with the signal intensity The signal intensity is affected by the distance from the voltage The further the tester is from the circuit the weaker the signal becomes Dual range When the tester is turned on it is in low sensitivity mode 48 1000V Briefly press the green button to enter the high sensitivity mode 12 1000V Refer to the followi...

Страница 3: ...re and live wire should not be distinguished by the screen color but by the detected signal intensity The live wire causes stronger signals and the neutral causes weaker signals It is recommended to activate the high sensitivity mode during identification Breakpoint testing Activate the high sensitivity mode move the tester s NCV tip along the cable the voltage alarm disappears when detected a bre...

Страница 4: ...tude 2000m Security level CE CAT III 1000V CAT IV 600V Batteries 2 1 5V AAA Battery replacement Rotate the battery cover off body remove the batteries and insert the positive terminal of the new battery toward the tip of the tester Rotate cap to the body until it is fully seated Before locking do not use the tester to test the electricity to avoid electric shock Cleaning Use only a soft slightly d...