P a g e |
2 3
P a g e |
2 2
©2018 Kaivac, Inc. All Rights Reserved |
www.kaivac.com
Customer/Technical Support |
1-800-287-1136
3.5 e
mPtying
v
acuum
t
ank
3.0 Operation
if the Vacuum motor shuts off before the job is complete, the Vacuum tank may be full and need to be
emptied. lift the Vacuum motor to check liquid level inside the Vacuum tank. if unit is full or your job is
complete, follow the instructions below to empty tank into appropriate sink/drain.
rinse Vacuum tank thoroughly at clean-up
sink, preferably with hot water.
rinse the Wand brushes to clear
any debris, and wipe dry.
For autoVac
TM
or suV
TM
, scrub debris
from Spreader pad with broom.
sweep debris. Vacuum if necessary.
remove debris from float ball and wire
mesh Float cage housing with hot water.
alternatively, you can
also turn Vacuum on and
dispense solution into
Vacuum Hose as shown
to clean Hose and Tank.
when work is complete, vacuum excess cleaning solution
from the bucket for 5 seconds to clean out and degrease
the Vacuum Hose.
Once cap is removed, lower dump Hose into
appropriate sink/drain. To prevent an accidental
spill or overflow from the dump Hose, be careful
to keep hose end upright until it is over sink/drain.
TiP: With Dispense-and-Vac, you can extend your cleaning range
with the following procedure:
1. thoroughly clean Vacuum tank.
2. Fill Vacuum tank and trolley-bucket with diluted cleaning
solution.
3. dispense solution onto floor.
4. when trolley-bucket is out of solution, use �ump �ose to refill
trolley from Vacuum tank.
5. continue dispensing.
To begin the dumping process, you must
first press down on the cap and turn
counter-clockwise
dumping from
Vacuum tank to
trolley-bucket
5 sec
PRESS
DOWN
TURN
4.1 d
aiLy
m
aintenance
: c
Leanout
4.0 Maintenance
Solution Dispenser