background image

Contents

Introduction to Sensedge 

4

Externals and air flow 

4

Connection ports 

4

Accessories 5

Sensor modules 

5

About the measurement 

6

Data buffer 

6

Sensedge First Use 

7

Charging the device 

7

Powering up the device 

7

Setting the language 

7

Connecting to Wi-Fi 

7

Setting a PIN code 

7

Views 8

Views: My Air 

8

Views: Data 

8

Views: Settings 

9

General 9

General > PIN 

9

General > Pair Device 

9

Sensors 9

Data Export 

10

Wi-Fi 10

Wi-Fi > Add Network (Hidden SSID) 

10

Ethernet 11

Screen 11

Language 11

Time 11

Device Details 

11

Device Details > Firmware Version 

11

Mounting the Sensedge 

13

Maintenance 13

Technical Specifications   

14

Endnotes 15

Содержание Sensedge

Страница 1: ...Sensedge Professional Indoor Air Quality Monitor Getting Started...

Страница 2: ......

Страница 3: ...ce 7 Setting the language 7 Connecting to Wi Fi 7 Setting a PIN code 7 Views 8 Views My Air 8 Views Data 8 Views Settings 9 General 9 General PIN 9 General Pair Device 9 Sensors 9 Data Export 10 Wi Fi...

Страница 4: ...erra com support Externals and air flow Air is drawn into the Sensedge from both the modules on the lower side as well as the air intake on the upper side It is vital that neither side of the device i...

Страница 5: ...ge Sensor modules Used to measure a variety of pollutants and other parame ters these sensors are interchangeable and modular Sensor modules The Sensedge utilises a modular design to allow for easy co...

Страница 6: ...ting with the Sensedge can have a measurable impact on temperature Changes in airflow or currents in an indoor space can all have a measurable impact on the readings of the Sensedge and correct usage...

Страница 7: ...Kaiterra logo appears on the screen Setting the language Upon first use the Sensedge will prompt users to select a language Scroll through the options using the touchscreen and confirm using the next...

Страница 8: ...using the menu on the left side of the screen Views My Air This is the default view displayed when the Sensedge is powered on and provides an overview of realtime air quality Realtime pollutants in th...

Страница 9: ...d from users at any point in time and anyone with access to the device may interact with it Require PIN Select Always to require the security PIN for all interaction with the device this should be cho...

Страница 10: ...l and other spreadsheet software Data export via e mail will only transfer readings that are stored in the cloud and not readings that are stored locally on the device and unavailable in the cloud If...

Страница 11: ...nguage of the device A number of languages are sup ported and may be modified at any point in time Upon change of language the device s screen may briefly dim as the interface is reloaded Time By defa...

Страница 12: ...both new features as well as security upgrades available By default auto update is enabled so that upgrades will be automatically installed when they become available online It is highly recommended...

Страница 13: ...gh the backplate Maintenance The Sensedge contains no customer serviceable components other than the modules inserted in the two module bays Neither the modules nor the Sensedge should never be opened...

Страница 14: ...ion 1 KM 100 Module 8 PM2 5 Sensor Type Light scattering 350nm Precision 9 10 10 30 g m3 3 g m3 Resolution 1 g m3 Range 1 1000 g m3 Measurable particle size 0 3 2 5 m Connection Wi Fi 2 4Ghz Ethernet...

Страница 15: ...defined upon fifteen minute averages Due to non uniform distribution of particulate matter fluctuations may occur at higher measurement frequency 10 The Sensedge is calibrated during the manufacturing...

Страница 16: ...d if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular in...

Отзывы: