KaiDeng WV-300W Скачать руководство пользователя страница 3

 

WV Grid-Tie Series

 

 

AC 0 angle with high precision auto-detection

 

AC phase angle of 0 through isolation amplifier then input to the MCU for high-precision detection and analysis. 

The phase shift rate is less than 1%, thus achieve high-precision with phase modulation AC output together. 

1

 

AC phase shift: < 1% 

2

 

Over-zero protection: 0.2 VAC 

3

 

AC switching: 50Hz / 60Hz 

Synchronous High-frequency Modulation 

In  the process of the grid, usually adapt the same phase angle in parallel.  (ie, When  the two-phase alternating 

current  total  is  equal  to  0.Use  switch  to  combination  the  two  AC  fusion)  and  the  product  is  rectified  AC 

half-frequency  AC  to  100Hz  first,  then  the  machine  use  the  high  frequency  current  in  the  circuit  and 

semi-100Hz frequency alternating current generated combination, to achieve high-frequency modulation. 

1

 

Modulation synthesis: half wave and full-bridge modulation synthesis (100Hz / 120Hz)   

2

 

Synthetic way: MOSFET full-bridge 

3

 

High frequency: 50KHz 

Pure Sine Wave Output 

Use SPWM directly to make pure sine wave output. 

1

Output waveform: Adopt complementary PWM to push-pull pure sine wave. 

2

Generate means: enhancement-mode SPWM

 

 

Automatic Sensing Function Solar Luminosity 

Use  the  latest  luminosity  perception  operation  technology.  The  different  illuminate  angle  and  intensity  of  the 

solar panel will produce different current output. Use advanced CPU to operate the different illuminance and the 

data can be directly displayed on the LCD. Then you can visually see the sense of the strength of the sun unit. 

Used more convenient. 

1

 

Luminosity sampling point 

power sampling point 

2

 

High precision AD sampling: integral AD sampling method 

Power Automatically Locked (APL) 

In  different  current  fluctuations,  we  should use  the  MPPT  function.  When  the  MPPT  function  adjusted  to  the 

maximum  power  point,  the  product  automatically  powers  locked  in  maximum  power  point,  then  made  the 

output power more stable. 

1

Power lock: The biggest sampling point of MPPT. 

Automatically Adapt To Different Load Power Factor

 

Adapt to any of the power load. 

 

Constant Current, Constant Power

 

This product is constant current, constant output power, without any overload, over-current phenomenon. 

 

Automatically Shut Down When The Power Output Of a Fault

 

When the city power system is in failure, the inverter will automatically turn off the output. 

 Current Limit Protection 

Current limit

 

 

Stack Multiple Machines 

 

 

Multiple small power inverters in parallel can achieve large output power.

 

 

High-Frequency High Conversion Rate

 

Adapt high frequency converter, the output more efficient. 

Maximum Power Point Tracking (MPPT) 

Because the current intensity and the voltage changes at any time, if there is no power point tracking, there 

will be a lot of problems. In the past time, usually adopt a solar controller, but this product uses high-precision         

MPPT operation power, automatic and immediate adjust the solar panels output power at the maximum output 

Содержание WV-300W

Страница 1: ...WV Grid Tie Series 1 WV 300 500W Series Inverters User Manual...

Страница 2: ...tiny then inverter will automatic open 6 grade power search function 1 The program can automatically open power adjustment for 6 times 2 The current direction can adjust from the maximum to the minim...

Страница 3: ...CPU to operate the different illuminance and the data can be directly displayed on the LCD Then you can visually see the sense of the strength of the sun unit Used more convenient 1 Luminosity samplin...

Страница 4: ...l gearbox When the engine speed increase while the gearbox gear don t increase at the same time it will definitely affect the speed of the car For traditional inverter speaking the parameter output po...

Страница 5: ...ing Show LED mode power instruction voltage instruction AC frequency instruction over voltage instruction Installation Wall hanging Cooling Fan Communication way 60KHz modulation power line carrier cu...

Страница 6: ...rter then make some loss G There must be a circuit breaker between solar power generation and power grid show like the control switch in figure 1 And there will be no load before the circuit breaker H...

Страница 7: ...of the terminal are connect fastness to avoid bad contact Show like figure 3 Figure 3 4 Operation After all connection first open the mains switch then open the inverter When the inverter s green LED...

Страница 8: ...connection Connection electrical diagram of the solar inverter used in single phase power generation system show below 7 Three phase connection Connection electrical diagram of the micro inverter used...

Страница 9: ...WV Grid Tie Series 9 Accessories for product One standard AC wire One user manual...

Отзывы: