background image

Page - 6

A

DJUSTING

 

THE

 D

ETENT

 F

ORCE

The spring plunger that provides the detent action can also be adjusted to vary
the force. Use a flat blade screw driver to move the plunger in and out as desired.
A convenient way to adjust the plunger is to screw the plunger all the way  in
until it gently bottoms out. Then unscrew the plunger about one complete turn.

Содержание 900

Страница 1: ...KiWi 900 950 User s Guide Photographic VR Panoramic Tripod Head Designed expresslyforthe Nikon Coolpix 900 900S and 950 Digital Cameras...

Страница 2: ...aforementioned items are copyrighted and subject to the laws concerning intellectual property Kaidan will replace defective software video tapes free of charge upon return receipt of defective item s...

Страница 3: ...yitems are missing oryou notice anydamage call Kaidan at 215 364 1778 between the hours of 9 00 AM and 6 00 PM EST Mon Fri The KiWi 900 950 also comes with two detent discs 14 and 18 positions not sho...

Страница 4: ...tional Nikon 24mm wide angle lens for the Coolpix 900 950 camera To remove the Friction Cap loosen the silver colored Retaining Knob which is lo catedonthesideoftheFrictionCap Itdoesnothavetoberemoved...

Страница 5: ...romNikonfortheCoolpix900 950 To install a different disc simply align the keyed slot and push the disc into the recess Make sure the disc is properly seated and flush to the bottom surface of the Vert...

Страница 6: ...etent action can also be adjusted to vary the force Use a flatblade screw driverto move the plungerin and outas desired A convenient way to adjust the plunger is to screw the plunger all the way in un...

Страница 7: ...ofthe 14 position detent disc MOUNTING THE CAMERA The KiWi 900 950 also comes with a Camera Adjustment Shoe to help keep your cameramountedvertically Italsomakesiteasytoremoveandreplaceyourcam era in...

Страница 8: ...roper mounting with the adjustment shoe in front of the camera Note theslotbelowthecameramountingholeswillacceptthecameraknoband can be used to locate the camera in accordance with the nodal points of...

Страница 9: ...unit is level Observe the twin axis bubble level on the KiWi 900 950 while leveling the tripod Of course this task is much easier if the tripod is equipped with a tilt head If the tripod does not have...

Страница 10: ...point to eliminate the image mismatch caused by parallax er ror Parallax error can be easily demonstrated by this simple experiment Close one eyeandholdyourindexfingeruprightaboutsixinchesawayfromyour...

Страница 11: ...the pan head so the two objects move over to the right hand side of the viewfinder Unless you ve managed to unwittingly locate the right nodal point position you should notice the two objects will mo...

Страница 12: ...ess Slide the bracket the same increment each time i e 10mm Placing a tem porarystrip of tape in order to measure and mark the increments should make iteasierto recordyourresults Be sure to record the...

Страница 13: ...e have included a friction pad cork strip to be used with the Coolpix 950 camera only See Fig A below for the correct placement NOTE If you are using the Coolpix 900 camera the cork does not need to b...

Отзывы: