Message
Possible cause
Remedy
0338 A
Oil cooler fan FC off -
STO?
Frequency converter parametrisa‐
tion incorrect.
Check the frequency converter
parametrisation.
Contact an authorised service
partner.
0380 A
Air cooler fan USS alarm
Frequency converter fault
Contact an authorised service
partner.
0381 A
Air cooler fan FC PKW
error P%d.E%d
Frequency converter fault
Contact an authorised service
partner.
0382 A
Air cooler fan USS
error %d
Alarm triggered by software driver. Contact an authorised service
partner.
0383 A
Air cooler fan FC
alarm %d
Frequency converter alarm mes‐
sage with message number.
Contact an authorised service
partner.
0384 A
Air cooler fan FC
activation failed
Fan frequency converter switched
on incorrectly.
Contact an authorised service
partner.
0387 A
Air cooler fan FC: STO
function inactive
Frequency converter parametrisa‐
tion incorrect.
Check the frequency converter
parametrisation.
Contact an authorised service
partner.
0388 A
Air cooler fan FC off -
STO?
Frequency converter parametrisa‐
tion incorrect.
Check the frequency converter
parametrisation.
Contact an authorised service
partner.
0500 A
I/O parameterisation
incorrect in module %d!
An I/O address has been assigned
more than once.
Display incorrect parametrisation
via the menu 1.1.3
Address error
and correct the parameter there
Tab. 89 Alarm messages, possible causes and remedies
10.3 Interpreting warning messages
If an input signal is classified as a warning, the controller will display a warning message
upon receiving the signal.
Consequences:
■ The
yellow LED flashes.
■ The controller does not switch off the machine.
Warning messages are indicated with the letter W.
Messages are not numbered consecutively.
In this table, “%d” represents a variable value, e.g. a number, period of time or I/O address.
1)
Messages 0073-0078, 0081-0096 and 0098 are customer-specific.
Add in the meaning for the message text you have defined (see chapter 8.12).
10 Fault Recognition and Rectification
10.3 Interpreting warning messages
206
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
No.: 9_9450 12 E