4. Inspect the air filter element for any damage.
Change the air filter element if damaged.
5. Clean the housing and sealing faces.
6. Replace the filter element.
7. Replace the cover and screw down tight.
8. Switch on the power supply disconnecting device.
10.7 Drive motor maintenance
The drive motor bearings are permanently greased. Re-greasing is not necessary.
➤ Have the motor bearings checked by an authorised KAESER Service.
10.8 Checking the oil level
The oil level can be read off on the oil sight glass.
Precondition The machine is switched off.
Fig. 31 Checking the oil level
1
Oil sight glass
2
Oil filler and crankcase vent
➤ Read off the oil level daily and before each start-up.
Result Top up when the compressor oil level falls to the minimum mark. Top up the oil
10.9 Topping up the compressor oil
Material Compressor oil
Precondition The supply disconnecting device is switched off.
The disconnecting device is locked off.
A check has been made that no voltage is present.
The machine has cooled down.
10 Maintenance
10.7 Drive motor maintenance
No.: 9_5753 24 E
Assembly and operating manual 2-stage piston compressor
EPC-2-G