Figure 35 Resolution-enhanced plot of Return Loss vs Distance
8.4.6 Overlay of PIM and Return Loss vs Distance Plots
36. This view is activated by pressing the OVL button at the top of the RTF Analysis window.
Figure 36 Overlay of PIM & Return Loss vs Distance plots
The controls and settings on this screen are identical to those of the PIM vs Distance and Return Loss vs Distance
plots described in Sections 8.4.2 and 8.4.5 respectively. The only new feature is the Marker Delta Indicator Δ, which is
displayed in the top right corner of the graticule underneath the PIM and Return Loss marker values. The Marker Delta
is a relative measurement giving the difference between the locations of the PIM and Return Loss peak markers. This
difference is given as an absolute value, hence it is always positive.
Marker Delta
Indicator
47