SET

SET

SET

SET

SET

SET

CHANGING PROGRAM

CHANGE menu could be reached by pressing ▲ button in PROG sub-menus.
NOTE: If there is no program on the memory, CHANGE menu does not exist.

SET button is pressed on CHANGE menu. The programs that has been 
set before, appear on the screen with using the direction buttons 
respectively.
SET button is pressed on desired program to change. 

 The program operation mode  is 
selected as astronomical or time 
switch. 

Astronomical mode

 

After making choice for the last day 
of the week, program could be stored 
with selecting SAVE or could be 
cancelled with selecting EXIT.

+ OFFSET : This parameter is used to adjust the program operation time. 

  OFFSET is added to sunrise or sunset time 

- OFFSET : This parameter is used to adjust the program operation time. 

  OFFSET is subtracted from sunrise or sunset time 

If timer mode is selected, 
hour,minute and second 
values are entered 
respectively.

Sunrise or Sunset is set
If it is desired,OFFSET would be 
adjusted.
 

For related program, desired relay output is 
selected. 

Required contact position is selected as ON 
or OFF 

If YES is selected, program 
operation is enabled  for flashing 
day.
If NO is selected, program is not 
used for flashing day.
This process is repeated for each 
day of the week.

A

B

A

B

SET

If ALL is selected, program operation is 
enabled for every day. If SELECT is selected, 
program operation is enabled for desired days.

www.kael.com.tr                  5

SET

SET

SET

SET

Time mode

A

B

A

B

SET

SET

SET

SET

SET

SET

Monday

Monday

SET

SET

Содержание ASTRO-30

Страница 1: ...ode Manual mode Relay B Lock function Quiet mode Manual mode 12 1 2 3 4 5 6 11 10 9 8 7 Clock faces represent output states of the relay contacts during current day Before midday am icon appears After midday pm icon appears There are two clock faces on the left for Relay A and on the right for Relay B Warnings The connection of device must be done by authorized technical service staff according to...

Страница 2: ... only way to deactivate this mode is manually Throughout the manual mode for changing Relay A output it is necessary to push and release button To deactivate this mode for Relay A push button until the hand icon disappears Permanent manual mode for Relay B Push and SET buttons at the same time until the hand icon appears on the right of the screen Permanent manual mode is not deactivated automatic...

Страница 3: ...splay EAST east ERR2 PIN code error ERR5 Program overload error EXIT exit HOUR hour LANGUA language LATITU latitude LOCATE locate STRT M start of quiet mode month STRT Y start of quiet mode year SUMMER summer SUNRSE sunrise SUNSET sunset T ZONE time zone TIME time UNUSED unused USED used UTC coordinated universal time W DAY winter beginning day W HOUR winter beginning hour W MIN winter beginning m...

Страница 4: ...sired relay output is selected Required contact position is selected as ON or OFF Monday If YES is selected program operation is enabled for flashing day If NO is selected program is not used for flashing day This process is repeated for each day of the week After making choice for the last day of the week program could be stored with selecting SAVE or could be cancelled with selecting EXIT DELETI...

Страница 5: ...ogram operation time OFFSET is added to sunrise or sunset time OFFSET This parameter is used to adjust the program operation time OFFSET is subtracted from sunrise or sunset time If timer mode is selected hour minute and second values are entered respectively Sunrise or Sunset is set If it is desired OFFSET would be adjusted For related program desired relay output is selected Required contact pos...

Страница 6: ...ed it is stored by pressing SET button Second parameter is beginning week for the summer in chosen month With using buttons week value is set as 1 2 3 4 or last Third parameter is beginning day for the summer With using buttons day is set Fourth parameter is beginning hour for the summer With using buttons hour value is set Fifth parameter is beginning minutes for the summer With using buttons min...

Страница 7: ... or negative offsets from UTC LOCK FUNCTION LOCK menu could be reached by pressing button in ADJUST sub menus This function could be used to prevent unauthorized persons from using the device If this function is enabled just for Relay A manual mode could not be activated for it But it is possible to activate manual mode for Relay B In this case for reaching the menus PIN code is required If this f...

Страница 8: ...tart Date is 20 03 2011 and stop date 25 03 2011 Quiet Mode starts on 20th March at 00 00 00 am and ends on 25th March at 23 59 59 During this time period Relay A would be off To activate Quiet mode just for 1 day start and stop date should be set as same day PIN PIN menu could be reached by pressing button in ADJUST sub menus If the LOCK function is enabled entering the pin code is required befor...

Страница 9: ...n in ADJUST sub menus By restoring an ASTRO to factory defaults following settings are installed Programs 4 preset programs Lock A B Off Quiet A B Off Manual A B Off Season Auto Location Contrast 7 NOTE Reset an ASTRO to factory defaults does not change the pin code and the real time adjust tıme season locate lock quıet pın langua TURKCE ENGLIS back adjust tıme season locate lock quıet pın languad...

Страница 10: ...vice Additional Reserv Time 3 7 hour Screen LCD Language English Turkish Programming with InfraRed No Mounting To connection rail in electrical panel Storage Temperature 10 ºC 70 ºC Ambient Temperature 0 ºC 50 ºC Device Protection Class IP 20 Connector Protection Class IP 00 Dimensions 2 x DIN modules 58mm 32mm 48mm 90mm 36mm 45mm 62mm 35mm 18 16 15 28 26 25 TECHNICAL DATA www kael com tr 9 CONNEC...