1.  Specifications

Model

RG66A1/BGEF

Rated voltage

3.0V (Dry batteries R03/LR03×2)

Signal receiving range

8m

Environment

-5ºC – 60ºC

2.  Function buttons

Before you begin using your new air conditioner, make sure to familiarise yourself with its remote control. The following
is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the
Basic functions and Advanced functions section of this manual.

Timer

Sleep

LED

Follow

me

Turbo

Short

Cut

Self

clean

Mode

Fan

ON/OFF

ON/OFF

Turns the unit on or off

MODE

Scrolls through operation

modes as follows:

AUTO 

➞ 

COOL 

➞ 

DRY

➞ 

HEAT 

 FAN

TIMER

Set timer to turn unit on and 

off (see Basic Functions  

for instructions)

SLEEP

Saves energy during

sleeping hours

LED

Turns indoor unit’s LED

display on and off

FOLLOW ME

Temperature sensing and room

temperature display button

TURBO

Enables unit to reach

preset temperature in

shortest possible time

FAN

Scrolls through fan speeds 

as follows:

AUTO 

➞ 

LOW 

MED 

 HIGH

NOTE: Holding this button

down for 2 seconds will

activate Silent mode

TEMP 

+

Increases temperature

in 1ºC increments.

(Max. temperature is 30ºC)

TEMP 

Decreases temperature

in 1ºC increments.

(Min. temperature is 17ºC)

SWING 

Starts and stops horizontal

louvre movement

SWING

Starts and stops vertical

louvre movement

SELF CLEAN

Starts and stops the

units self-clean feature

SHORT CUT

Sets and activates your

favourite settings

Содержание KCS Series

Страница 1: ...Remote Controller Manual CASSETTE AIR CONDITIONER KCS Series KCS24 KCS36 KCS42 KCS48 Mode ON OFF Fan Timer Sleep LED Follow me Turbo Short Cut Self clean...

Страница 2: ......

Страница 3: ...Y operation dehumidifying 8 FAN operation 8 HEAT operation 9 Setting the TIMER function 10 Setting both TIMER ON and TIMER OFF at the same time 11 6 Advanced functions 13 SLEEP function 13 TURBO funct...

Страница 4: ...es as follows AUTO COOL DRY HEAT FAN TIMER Set timer to turn unit on and off see Basic Functions for instructions SLEEP Saves energy during sleeping hours LED Turns indoor unit s LED display on and of...

Страница 5: ...als properly 2 Install the holder with two screws 3 Put the remote controller in the holder Battery notes For optimum product performance Do not mix old and new batteries or batteries of different typ...

Страница 6: ...Displays when TIMER ON is set ON TIMER OFF display Displays when TIMER OFF is set OFF Silent feature display Follow me feature display LOCK feature display Sleep mode display Battery display Low batte...

Страница 7: ...ED can t be set in Auto mode COOL operation 1 Press the MODE button to select COOL mode 2 Set your desired temperature using the Temp or Temp button 3 Press the FAN button to select the fan speed 4 Pr...

Страница 8: ...t be set in DRY mode FAN operation 1 Press the MODE button to select FAN mode 2 Press the FAN button to select the fan speed 3 Press the ON OFF button to start the unit NOTE You can t set temperature...

Страница 9: ...the FAN button to select the fan speed 4 Press the ON OFF button to start the unit NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such instances we...

Страница 10: ...s you to set a period of time after which the unit will automatically turn off such as when you wake up 1 Press the Timer button the Timer off indicator displays and flashes By default the last time p...

Страница 11: ...hours after the current time For example say that the current time is 1 00 PM and you want the unit to turn on automatically at 7 00 PM You want it to operate for 2 hours then automatically turn off...

Страница 12: ...rate for 2 hours then turn off see figure below Your remote display 6 hours later 8 hours later Timer starts Unit turns ON 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM Current time 1PM Timer is set to turn ON 6 ho...

Страница 13: ...temperature in the shortest amount of time possible When you select TURBO feature in COOL HEAT mode the unit will blow cool hot air with strongest wind setting to jump start the cooling heating proces...

Страница 14: ...nction Swing button Used to stop or start vertical louvre movement and set the desired left right air flow direction The vertical louvre changes 6 degrees in angle for each press If held down for more...

Страница 15: ...e current settings or resume previous settings If this button is pushed when the remote controller is on the system will automatically revert back to the saved settings including operating mode settin...

Страница 16: ...kadenair com au...

Отзывы: