1. Safety precautions

Read safety precautions before operation and installation

Incorrect installation due to ignoring instructions can cause serious damage or injury.

The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.

WARNINGS FOR PRODUCT USE

This symbol indicates the possibility of property damage or serious consequences.

This symbol indicates the possibility of personal injury or loss of life.

 

Do not

 share the electrical outlet with other appliances. 

Improper or insufficient power supply can cause fire or 
electrical shock.

 When connecting refrigerant piping, 

do not

 let 

substances or gases other than the specified refrigerant 
enter the unit. The presence of other gases or 
substances will lower the unit’s capacity, and can cause 
abnormally high pressure in the refrigeration cycle.  
This can cause explosion and injury.

 

Do not

 allow children to play with the air conditioner. 

Children must be supervised around the unit at all times.

1. Installation must be performed by a licensed installer.

Defective installation can cause water leakage, electrical
shock, or fire.

2. Installation must be performed according to the

installation instructions. Improper installation can cause
water leakage, electrical shock, or fire.

3. Contact an authorised service technician for repair or

maintenance of this unit.

4. Only use the included accessories, parts, and specified

parts for installation. Using non-standard parts can cause
water leakage, electrical shock, fire, and can cause the
unit to fail.

5.  Install the unit in a firm location that can support the unit’s

weight. If the chosen location cannot support the unit’s
weight, or the installation is not done properly, the unit
may drop and cause serious injury and damage.

6.  Only fully qualified licensed personnel should install

service or carry out maintenance to this air conditioning
unit. All electrical work is to follow local and national
wiring standards and the Installation Manual.

7.  You must use an independent circuit and single outlet to

supply power. 

Do not

 connect other appliances to the

same outlet. Insufficient electrical capacity or defects in
electrical work can cause electrical shock or fire.

8.  For all electrical work, use the specified cables. Connect

cables tightly, and clamp them securely to prevent
external forces from damaging the terminal. Improper
electrical connections can overheat and cause fire, and
may also cause shock.

9.  All wiring must be properly arranged to ensure that

the control board cover can close properly. If the
control board cover is not closed properly, it can lead
to corrosion and cause the connection points on the
terminal to heat up, catch fire, or cause electrical shock.

10. In certain functional environments, such as kitchens,

server rooms, etc., the use of specially designed air-
conditioning units is highly recommended.

11. This appliance can be used by children aged from 8

years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children must not
play with the appliance. Cleaning and user maintenance
must not be made by children without supervision.

Содержание KCI36

Страница 1: ...Installation Manual CASSETTE AIR CONDITIONER KCI Series KCI36 KCI42 KCI48...

Страница 2: ...000 AS NZS 5149 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For continued safe...

Страница 3: ...n pipe length 18 Connection instructions Refrigerant piping 19 Note on minimum bend radius 21 7 Wiring 22 Note on isolator 22 Outdoor unit wiring 23 Indoor unit wiring 24 Power specifications 25 8 Lea...

Страница 4: ...5 Install the unit in a firm location that can support the unit s weight If the chosen location cannot support the unit s weight or the installation is not done properly the unit may drop and cause s...

Страница 5: ...ARC Australian Refrigeration Council licence holders can install and commission this air conditioner This air conditioner must be installed to meet the requirements of the current version of AS NZS 51...

Страница 6: ...6 Kaden Installation Manual...

Страница 7: ...of accessories Qty pc Shape Name of accessories Qty pc Shape Owners Installation Remote Controller Manuals 3 Drain joint 1 Soundproof insulation sheath 1 Seal ring 1 Soundproof insulation sheath 1 Co...

Страница 8: ...Install the indoor unit Install the drainpipe Install the outdoor unit Pressure test and evacuation Connect the power wires Connect the refrigerant pipes Install the front panel Perform a test run 1...

Страница 9: ...ghtly different in different areas Note on illustrations Illustrations in this manual are for explanatory purposes The actual shape of your indoor unit may be slightly different 1 Air outlet 2 Air inl...

Страница 10: ...can fill the entire room There is no direct radiation from heaters DO NOT install unit in the following locations Areas with oil drilling or fracking Coastal areas with high salt content in the air Ar...

Страница 11: ...sides The cut hole size should be 40mm larger than the body size Be sure to mark the areas where ceiling hook holes will be drilled KCI36 48 models ceiling hole size Refrigerant piping side Drain hos...

Страница 12: ...on bolts into the unit s hanging holes Fasten them using the included washers and nuts NOTE The bottom of the unit should be 10 18mm higher than the ceiling board Generally L indicated in the followin...

Страница 13: ...water drainage 3 Place the protective wall cuff in the hole This protects the edges of the hole and will help seal it when you finish the installation process CAUTION When drilling the wall hole make...

Страница 14: ...the unit and the lift pipe must be less than 300mm Incorrect installation could cause water to flow back into the unit and flood To prevent air bubbles keep the drain hose level or slightly sloping u...

Страница 15: ...The minimum height must be 45cm above the base pad DO NOT install unit in the following locations Near an obstacle that will block air inlets and outlets Near a public street crowded areas or where no...

Страница 16: ...wing 1 Insert the drain joint into the hole in the base pan of the unit The drain joint will click in place 2 Connect a drain hose extension not included to the drain joint to redirect water from the...

Страница 17: ...ance A Distance B 952mm x 1333mm x 415mm 634mm 404mm Rows of series installation The relationships between H A and L are as follows L A L H L 1 2H 250mm or more 1 2H L H 300mm or more L H Can not be i...

Страница 18: ...is installed higher than the outdoor unit If oil flows back into the outdoor unit s compressor this might cause liquid compression or deterioration of oil return Oil traps in the rising gas piping can...

Страница 19: ...urrs Burrs can affect the air tight seal of refrigerant piping connection They must be completely removed 1 Hold the pipe at a downward angle to prevent burrs from falling into the pipe 2 Using a ream...

Страница 20: ...w pressure pipe then the high pressure pipe 1 When connecting the flare nuts apply a thin coat of refrigeration oil to the flared ends of the pipes 2 Align the centre of the two pipes that you will co...

Страница 21: ...le with other wires While bundling these items together do not intertwine or cross the signal cable with any other wiring 7 Thread this pipeline through the wall and connect it to the outdoor unit 8 I...

Страница 22: ...s all poles and has a contact separation of at least 3mm 1 8 in must be incorporated in the fixed wiring The qualified technician must use an approved circuit breaker or switch 7 Only connect the unit...

Страница 23: ...exceeds 30M in length 2 5mm thick cable should be used The cable specifications are based on the assumption that a metal or plastic conduit is used with no more than three cables contained in a condui...

Страница 24: ...al block Firmly screw the u lug of each wire to its corresponding terminal 7 Clamp down the cable with the wire clamp 8 The power cables and interconnect power cables will enter the unit separately th...

Страница 25: ...ssories CAUTION While connecting the wires please strictly follow the wiring diagram The refrigerant circuit can become very hot Keep the interconnection cable away from the copper tube 5 Clamp down t...

Страница 26: ...a leak detector and bubble solution Safely release the test pressure 4 Open the low pressure side of the manifold gauge Keep the high pressure side closed 5 Turn on the vacuum pump to evacuate the sys...

Страница 27: ...valve by turning the wrench in a 1 4 counter clockwise turn Listen for gas to exit the system then close the valve after 5 seconds 2 Watch the pressure gauge for one minute to make sure that there is...

Страница 28: ...en the panel hook screws evenly at the four corners NOTE Tighten the screws until the thickness of the sponge between the main body and the panel reduces to 4 6mm The edge of the panel should be in co...

Страница 29: ...d drainpipe are not affected by this adjustment CAUTION Failure to tighten screws can cause water leakage CAUTION If the unit is not hung correctly and a gap exists the unit s height must be adjusted...

Страница 30: ...c Double check to see if the room temperature is being registered correctly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual but...

Страница 31: ...erature sensor T4 is in open circuit or has short circuited 5 times EC 54 Compressor discharge temperature sensor TP is in open circuit or has short circuited 5 times EC 55 Outdoor Inverter IPM Board...

Страница 32: ...kadenair com au...

Отзывы: