READER INSTALLATION

 

 

Separate the back cover with holes and use as a template 

 

Drill 2 holes (A, C) in the wall of the bolt and one under the cable 

 

Insert the bolt holes (A, C) attached dowels 

 

Screw the rear part of the housing to the wall using the screws 

 

Bring out the controller cables through the hole (B) 

 

Mount  the  controller  on  the  base  and  secure  it  from  below  with  a  special 

screw 

Wiring Diagram 

 

Red

 

+12V DC

 

Black

 

GND

 

Green

 

D0

 

White

 

D1

 

Brown

 

LED

 

Yellow

 

Buzzer

 

Change card Wiegand output format procedure:  

 

- 26 bit Wiegand  (Unique, Mifare)    -   * 1 2 3 4 5 6 # 7 2 

26

 # * *   -  exit 

 

- 34 bit Wiegand  (Unique, Mifare)    -   * 1 2 3 4 5 6 # 7 2 

34

 # * *   -  exit 

 

- 26 & 37 bitów (HID Prox) - automatic, depend of card number  

 

Change PIN output format procedure: 

 

- Virtual card number format           -   * (1 2 3 4 5 6) # 7 3 0 # * *   -   exit 

 

- 4 bit format (KaDe)                      -   * (1 2 3 4 5 6) # 7 3 1 # * *   -   exit 

 

- 8 bit format (Kantech)                  -   * (1 2 3 4 5 6) # 7 3 2 # * *   -   exit 