Installation and Start-up
Page 14
Operating manual Powador-piccoLOG_EN
5.4
Connecting the inverter
654321
RS485 B
RS485 A
1
2
3
4
5
6
GND
+24V
A
B
RJ12
A
B
1
2
3
4
5
6
Figure 4: Connecting the inverter
1
RJ12 plug/ RS485
4
RS485 B / RS485- / -TR / T-
2
Signal name
5
RS485 A / RS485 + / +TR /
T+
3
Bus cable (twisted and shielded wire
pair) for the Powador-piccoLOG
6
Inverter
NOTE
See the inverter manual for details on bus configuration.
•
To connect, use a ready-made connection cable or manufacture
one according to the above pin configuration.
•
We recommend the use of
UNITRONIC® Li2YCYv
(TP) cables,
produced by "
LappKabel
", or equivalent. This cable is suitable for
installation directly into the earth.
Bus configuration
"
Remove protective cover.
"
Connect inverter with an RJ12 connection jack (see 5.2
"
Interface
overview
"
).
»
If there is no inverter already installed, the device will automatically search
for an inverter once switched on.
»
Perform a manual search with the software
(see 5.9 "Powador-piccoLOG Device Manager").