Fig. 15: Placing the wires
Fig. 16: Tightening the wires
Fig. 17: Interconnection
Fig. 18: Tightening the cable fitting
7.3.3
Connecting the connector
Latch the assembled connector with the device connector (Fig. 19: Connecting the connector Fig. 20 Minimum bending
radius). Observe the required minimum bending radii when laying the cable (Fig. 19: Connecting the connector Fig. 20
Minimum bending radius).
CAUTION
Plug in or disconnect connectors
Never connect or disconnect the connectors under load. The connectors are not suitable for disconnecting
the power.
Fig. 19: Connecting the connector
Fig. 20 Minimum bending radius
7.3.4
Technical data
Protection rating
IP65/IP68 (2m, 24h)
Nominal current
35 A (observe the derating and the cable cross-section)
Nominal voltage
690 V
Authorised elec-