blueplanet Operating and Installation Instructions 1502xi - 5002xi 31000770-02-112609
Page 3
3.2 Factory warranty and liability
KACO new energy GmbH issues a warranty of ten years or 120
months on the blueplanet inverter starting from the date of
installation, but at most 130 months after shipment by KACO
new energy GmbH.
During this time, KACO new energy GmbH guarantees the
proper function of the units and to undertake repairs at the
factory free of charge in the event of a defect for which we
are responsible.
Contact your specialty dealer or installer if your unit exhibits a
defect or fault during the warranty period.
Warranty claims are excluded in the following cases:
– Use of the units in ways not intended
– Improper installation and installation that does not comply
with standards
– Improper operation
– Operation of units with defective protective equipment
– Unauthorized modifications to the units or repair attempts
– Influence of foreign objects and force majeure (lightning,
overvoltage, severe weather, fire)
– Insufficient ventilation of the unit
– Failure to observe the relevant safety regulations
– Transport damage
All warranty claims must be handled at the premises of KACO
new energy GmbH. The unit must, where possible, be returned
in its original or equivalent packaging. The costs for these
services cannot be borne by KACO new energy GmbH.
KACO new energy GmbH will perform warranty services only
if the defective unit is returned to KACO new energy GmbH
together with a copy of the invoice which was issued to the
user by the dealer and the completed warranty card. The name
plate on the unit must be fully legible. If these requirements
are not fulfilled, KACO new energy GmbH reserves the right to
deny warranty services.
The warranty period for repairs or replacement deliveries is six
months after delivery. However, it continues at least until the
end of the original warranty period for the delivery item.
3.3 Service
We place special emphasis on the quality and longevity of our
inverters, starting with the product development phase. More
than 60 years of experience in the field of power conversion
device manufacturing support our philosophy.
However, despite all quality assurance measures, faults may
occur in exceptional cases. In such cases, KACO new energy
GmbH will provide you with the maximum possible support.
KACO new energy GmbH will make every effort to remedy
such faults in an expeditious manner and without a great deal
of bureaucracy. Contact our service department directly by
telephone at + 1 866 522 6765.
!
CAUTION
Incorrect use is prohibited.
4 Operation
The grid-feed process begins in the morning if sufficient
insolation is available, and, therefore, if a certain minimum
voltage is present in the inverter.
If, as nightfall approaches, the voltage drops below the
minimum voltage value, grid-feed mode ends and the inverter
switches off.
4.1 Overview of controls and displays
Figure 4.1:
Overview blueplanet
Legend
1
Display
See measured values and configuration parameters
2
LED displays
Display of the operating state
3
Control keys
Switch between displays and configuration of
parameters
4
Night time start switch
For activating the display after nightfall
5
GFDI fuse
Ground Fault Detector Interruptor Fuse.
6
AC/DC switch
Disconnects AC and DC power from the inverter
Section 3 ·
Notes on Installation and Operation
Section 4 ·
Operation
Содержание blueplanet 1502xi