6.
KABI Digital meter oil control gun
CHANGING THE CORRECTION FACTOR
1. Press TOTAL two times, then press RESET over 3 to 5 seconds to activate program-
ming mode, the first digit [0] flashes, the display shows the original correction factor.
2. Choose the next digit by pressing the TOTAL button. The chosen digit is flashing.
3. Press the RESET button to add [1] and adjust the numbers to be identical to your
calculated new Meter correction factor.
4. Press RESET and TOTAL at same time, for 3 to 5 seconds to exit programming mode.
CHANGING THE MEASUREMENT UNIT
1. Press TOTAL two times, then press RESET for 3 to 5 seconds to enter programming
mode.
2. Press the TOTAL button until the measurement unit sign flashes.
3. Use RESET to choose between the units L, GAL, PT and QT.
4. Press RESET and TOTAL at same time, for 3 to 5 seconds to exit programming mode.
After presetting the meter, push the button on the nozzle to release the
pressure of nozzle.