KABI 40191 Скачать руководство пользователя страница 3

KABI Rotary Pump

Please read and save these instructions. Read 

carefully before attempting to assemble, install, 

operate or maintain the product described. 

Protect yourself and others by observing all safety 

information. Failure to comply with instructions 

could result in personal injury and/or property 

damage! Retain instructions for future reference.

DESCRIPTION

This KABI Rotary Rotary Pump is commonly used 

for dispensing or transferring diesel oil, heating oil, 

lubricating oil, engine oil, gear oil, hydraulic oil and 

other non-corrosive fluids compatible with pump 

materials of construction.

The pump is designed to deliver 38 L/min at 135 RPM. 

This pump is a self-priming unit. The pump is supplied 

with a 2” BSP (M) bung adapter designed to fit most 

50-200 L drums. 

This pump is not suitable for use with gasoline, 

water-based liquids and alkaline liquids.

UNPACKING

When unpacking the unit, inspect carefully for any 

damage that may have occurred during transit.

Check for loose, missing, or damaged parts. Transit 

damage claims should be made to the shipping 

company.

SPECIFICATIONS

Pump Type

Rotary

Flow

34 L/min at 135 RPM

Max. Fluid Temperature

60°C (140°F)

Mounting

2” BSP (M) Bung 

Adapter

Inlet Size

1” BSP (F)

Outlet Size

3/4” BSP (F)

40191 outlet

Curved Discharge Spout

40191S outlet

Curved Discharge Spout 

with 1 mtr. leading hose 

and elbow spout

Wetted Materials of 

Construction

Steel, Cast Iron, and 

Buna Rubber

Maximum Viscosity

1000 cSt (40°C)

WARNING

Never use the pump for pumping liquids like 

gasoline, alcohol, acetone, thinners, acids or any 

other flammable or explosive liquids. Any use of 

the KABI Rotary Pump with these liquids, as well as 

using the pump in work areas with any flammable 

or explosive liquids, can cause serious bodily injury 

or death and/or cause property damage.

ASSEMBLY AND INSTALLATION

1.  Screw discharge spout into the pump body outlet 

using Teflon tape or equivalent sealant tape. Do not 

use paste pipe sealant. 

2.  Slide the handle over the handle shaft and 

assemble to the crank arm using a hex nut. Attach 

the entire crank arm subassembly, including 

handle, handle shaft, and hex nut, onto the pump 

shaft taking care to align set screw to indent in the 

rotor shaft.

3.  Thread suction tube into pump body inlet using 

Teflon tape or equivalent sealant tape. Do not use 

paste pipe sealant. 

4.  Thread bung adapter assembly into drum.

5.  Insert pump and suction tube assembly into bung 

adapter and hand-tighten bung adapter set screw. 

Be sure to set pump and suction tube assembly so 

that the suction tube is at the desired depth in the 

barrel and is not blocked.

OPERATION

1.  Check hoses for weak or worn conditions before 

each use, making certain that all connections are 

secure.

2.  To begin pumping fluid, rotate handle clockwise 

several times making complete revolutions until 

fluid begins to flow. Several revolutions will be 

made with no fluid dispensed as pump needs to 

prime. Once primed, fluid flow begins as handle is 

rotated.

3.  For siphoning or draining fluid back into barrel, 

place handle in the straight down position.

4.  To stop siphoning and maintain suction or prime, 

leave handle in horizontal position.

Regularly check pump and suction tubes for leaks. 

Leaks in the suction line or in pump housing will cause 

inefficient pumping and loss of prime.

3.

Содержание 40191

Страница 1: ...p Roterende Pumpe Kiertopumppu KABI A S Kokkedalsvej 29 DK 2970 H rsholm Denmark Phone 45 4576 0242 Fax 45 4576 4468 Mail kabi kabi dk Web www kabi dk Operating Manual 3 Brugsvejledning 4 Bruksanvisni...

Страница 2: ...2...

Страница 3: ...r any other flammable or explosive liquids Any use of the KABI Rotary Pump with these liquids as well as using the pump in work areas with any flammable or explosive liquids can cause serious bodily i...

Страница 4: ...syrer eller nogen andre brandbare eller eksplosive v sker Enhver anvendelse af KABI Rotationspumpen med disse typer v sker s vel som anvendelse af pumpen p arbejdsomr der med brandbare eller spr ngfa...

Страница 5: ...eller explosiva v tskor Anv ndning av KABI rotationspump med dessa v tskor samt anv ndning av pumpen i arbetsomr den med brandfarliga eller explosiva v tskor kan orsaka allvarlig kroppsskada eller d d...

Страница 6: ...nnfarlige eller eksplosive v sker Bruk av den roterende pumpen fra KABI med disse v skene s vel som bruk av pumpen i arbeidsomr der med brannfarlige eller eksplosive v sker kan for rsake alvorlig pers...

Страница 7: ...e kuten bensiini alkoholi asetoni tinnerit hapot tai muut syttyv t tai r j ht v t nesteet KABI kiertopumpun k ytt minen n ille nesteille tai pumpun k ytt minen alueilla joilla on syttyvi tai r j ht vi...

Страница 8: ...Your worldwide partner in Fluid Handling Solutions www kabi dk GKAMANUAL40191 V 1...

Отзывы: