Condition
Parameters
Green LED
Red LED
Duration
Rate
Valid pushbutton
ON
OFF
1/10 sec
Once
pressed
Timeout expired
OFF
ON
1 sec; A
Once
Valid access
ON
OFF
1 sec
Once
code keyed
Access granted
ON
OFF
1/10 sec
1 sec
Access granted
ON
ON
1/10 sec
1 sec
(battery low condition)
Access denied
OFF
ON
1 sec; A
Once; B
Valid programming
ON
OFF
1 sec
Once
entry
Invalid programming
OFF
ON
1 sec; A
Once; B
entry (including
duplicate access code)
Tamper shutdown
OFF
ON
2 sec
Once
beginning
Tamper shutdown state
OFF
ON
1 sec; C
10 sec
Tamper shutdown
ON
OFF
2 sec; C
Once
ending
Visual Feedback Message Definitions
Summary of Pushbutton Programming Commands
Name
Diagnostic
Command
500 #
123456789*0#
Description of Command
‘Manual diagnostic’
www.kabaaccess.com
Quick
Reference
Guide
PKG3172 0313
For PowerPlex 2000 only:
Lock is ready when front
ON
OFF
1/10 sec
Once
lever is depressed
Lock’s stored power is
OFF
ON
1/10 sec
1 sec
starting to fade
A
= 1/10 second; B = Twice; C = Can be observed only when you pump the lock’s lever
E2000 Operation:
Enter your valid PIN to Access the lock and/or to program the
lock at its keypad.
PowerPlex 2000 Operation:
This model is a self-powered lock. To access and/or
program the lock, you must first generate power by depressing the front lock
lever down at least once. This energizes the lock temporarily for a few seconds ,
enough time for you to enter your PIN and open the lock, or start to program the
lock with a command sequence.
Name
Configur
Command
000 #
MMMMMMMM#
MMMMMMMM#
004 #
TT#
005 #
TT#
006 #
TT#
007 #
TT#
008 #
VV#
009 #
LL#
099 #
Description of Command
‘Modify Master User Access Code (lock’s
activation)’ (Always 8 digits)
‘Unlock time setup’ (TT = 02 to 20 seconds)
‘Passage Mode Timeout setup’ (TT = 01 to 24
hours - duration time in hours; 00 = no time limit)
Note: Not applicable to PowerPlex 2000 models
‘Tamper time setup’ (TT = 00 to 90 seconds)
‘Tamper wrong try setup’ (TT = 03 to 09)
‘Buzzer volume control’ (VV = 00 to 03; 00 = off;
01 = Low; 02 = Normal; 03 = High)
‘Modify access length’ (LL = 04 to 08 digits)
‘Reset to factory default values’, except access
code length. (Master, manager and access user
are retained if already programmed.)
Summary of Pushbutton Programming Commands
To begin, put lock in programming mode by pressing: #Master Code#
2000 Series
Series