WSSKP-1 Installation & Programming Guide
7
Operational Modes and Program Codes
The WSSKP-1 can be used in one of three operating modes:
Standalone
Wiegand
Combined standalone/Wiegand
The following table indicates applicable Program Codes for each of the Operational Modes.
Program Codes / Code Options / Operation Modes Chart
Program
Code
Program Code Options
Standalone
Operation
Wiegand
Operation
Combined
Operation
Code 0 –
Combination
Outputs
0 =
Wiegand and digital
output on valid PIN –
# key not required
after PIN entry
(Default)
1 =
Wiegand and digital
output on valid PIN -
# key required after
PIN entry
2 =
Wiegand or digital
output on valid PIN –
# key not required
after PIN entry
3 =
Wiegand or digital
output on valid PIN –
# key required after
PIN entry
Code 1 –
Wiegand
Format
26 = 26 bit Wiegand format
36 = Keyscan proprietary
format (Default)
Code 2 –
Facility
Code
0 to 255
0 (Default)
Code 3 –
Master Code
1 to 9999
9571 (Default)
Code 5 –
Digital
Output
Status
0 = Switched Off – Normally
Open (Default)
1 = Switched On – Normally
Closed
Code 6 –
Digital
Output Time
0 to 255 seconds
5 seconds (Default)
Code 7 –
Digit Length
of PIN
3 to 5 digits
5 digits (Default)